Biomechanical comparison of three fixation techniques used for four-corner arthrodesis
- PMID: 21636620
- DOI: 10.1177/1753193411406799
Biomechanical comparison of three fixation techniques used for four-corner arthrodesis
Abstract
Clinical results following four-corner arthrodesis vary and suggest that nonunion may be related to certain fixation techniques. The purpose of our study was to examine the displacement between the lunate and capitate following a simulated four-corner arthrodesis with the hypothesis that three types of fixation (Kirschner wires, dorsal circular plate, and a locked dorsal circular plate) would allow different amounts of displacement during simulated wrist flexion and extension. Cadaver wrists with simulated four-corner arthrodeses were loaded cyclically either to implant failure or until the lunocapitate displacement exceeded 1 mm. The locked dorsal circular plate group was significantly more stable than the dorsal circular plate and K-wire groups (p = 0.018 and p = 0.006). While these locked dorsal circular plates appear to be very stable our results are limited only to the biomechanical behavior of these fixation techniques within a cadaver model.
Similar articles
-
Biomechanical comparison of the holding strength of a peek-optima circular plate versus a stainless steel oblique T-plate for radioscapholunate arthrodesis.J Hand Surg Am. 2008 Dec;33(10):1765-9. doi: 10.1016/j.jhsa.2008.08.023. J Hand Surg Am. 2008. PMID: 19084175
-
Outcome of four-corner arthrodesis for advanced carpal collapse: circular plate versus traditional techniques.Acta Orthop Belg. 2009 Jun;75(3):323-7. Acta Orthop Belg. 2009. PMID: 19681317
-
Results of four-corner arthrodesis using dorsal circular plate fixation.J Hand Surg Am. 2005 Sep;30(5):903-7. doi: 10.1016/j.jhsa.2005.04.007. J Hand Surg Am. 2005. PMID: 16182043
-
[Arthrodesis of the wrist in arthritis].Orthopade. 1996 Apr;25(2):121-5. Orthopade. 1996. PMID: 8692564 Review. German.
-
Radioscapholunate arthrodesis for advanced degenerative radiocarpal osteoarthritis.Tech Hand Up Extrem Surg. 2007 Sep;11(3):180-3. doi: 10.1097/BTH.0b013e3180413883. Tech Hand Up Extrem Surg. 2007. PMID: 17805154 Review.
Cited by
-
Locking Dorsal Plate in Four-Bone Arthrodesis in SLAC and SNAC 3 Wrist.Joints. 2018 Feb 12;6(1):37-41. doi: 10.1055/s-0038-1626738. eCollection 2018 Mar. Joints. 2018. PMID: 29675505 Free PMC article.
-
The Effect of Proximal Hamate Osteotomy on Carpal Kinematics for Reconstruction of Proximal Pole Scaphoid Nonunion With Avascular Necrosis.Hand (N Y). 2020 May;15(3):371-377. doi: 10.1177/1558944718793175. Epub 2018 Aug 20. Hand (N Y). 2020. PMID: 30124083 Free PMC article.
-
Effectiveness of four-corner arthrodesis with use of a locked dorsal circular plate.Clin Orthop Relat Res. 2012 Oct;470(10):2764-70. doi: 10.1007/s11999-012-2312-9. Epub 2012 Mar 20. Clin Orthop Relat Res. 2012. PMID: 22430314 Free PMC article.
-
Four-Corner Arthrodesis: Comparative Analysis of Open Technique Versus Percutaneous Technique with Arthroscopic Assistance.J Wrist Surg. 2021 Oct 1;11(2):127-133. doi: 10.1055/s-0041-1735838. eCollection 2022 Apr. J Wrist Surg. 2021. PMID: 35478943 Free PMC article.
-
Four corner fusion using a multidirectional angular stable locking plate.World J Orthop. 2016 Aug 18;7(8):501-6. doi: 10.5312/wjo.v7.i8.501. eCollection 2016 Aug 18. World J Orthop. 2016. PMID: 27622151 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources