Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2011 Oct;69(4):815-20; discussion 820-1.
doi: 10.1227/NEU.0b013e318226632c.

Adenosine for temporary flow arrest during intracranial aneurysm surgery: a single-center retrospective review

Affiliations
Review

Adenosine for temporary flow arrest during intracranial aneurysm surgery: a single-center retrospective review

Bernard R Bendok et al. Neurosurgery. 2011 Oct.

Abstract

Background: Clip application for temporary occlusion is not always practical or feasible. Adenosine is an alternative that provides brief periods of flow arrest that can be used to advantage in aneurysm surgery, but little has been published on its utility for this indication.

Objective: To report our 2-year consecutive experience with 40 aneurysms in 40 patients for whom we used adenosine to achieve temporary arterial occlusion during aneurysm surgery.

Methods: We retrospectively reviewed our clinical database between May 2007 and December 2009. All patients who underwent microsurgical clipping of intracranial aneurysms under adenosine-induced asystole were included. Aneurysm characteristics, reasons for adenosine use, postoperative angiographic and clinical outcome, cardiac complications, and long-term neurological follow-up with the modified Rankin Scale were noted.

Results: Adenosine was used for 40 aneurysms (10 ruptured, 30 unruptured). The most common indications for adenosine were aneurysm softening in 17 cases and paraclinoid location in 14 cases, followed by broad neck in 12 cases and intraoperative rupture in 6 cases. Troponins were elevated postoperatively in 2 patients. Echocardiography did not show acute changes in either. Clinically insignificant cardiac arrhythmias were noted in 5 patients. Thirty-six patients were available for follow-up. Mean follow-up was 12.8 months. The modified Rankin Scale score was 0 for 29 patients at the time of the last follow-up. Four patients had an modified Rankin Scale score of 1, and scores of 2 and 3 were found in 2 and 1 patients, respectively.

Conclusion: Adenosine appears to allow safe flow arrest during intracranial aneurysm surgery. This can enhance the feasibility and safety of clipping in select circumstances.

PubMed Disclaimer

LinkOut - more resources