Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Jun;34(5):306-13.
doi: 10.1016/j.jmpt.2011.04.006. Epub 2011 May 14.

Palpatory accuracy of lumbar spinous processes using multiple bony landmarks

Affiliations

Palpatory accuracy of lumbar spinous processes using multiple bony landmarks

Karen T Snider et al. J Manipulative Physiol Ther. 2011 Jun.

Abstract

Objective: Accurate localization of vertebral segments is crucial for many treatment procedures. The objective of this study was to determine accuracy of identification of lumbar spinous process levels by palpation.

Methods: Three examiners independently identified the spinous processes of L1-L4 on 60 prone volunteers using multiple bony landmarks including the sacral base, L5, Tuffier's line, T12, and the 12th ribs. The spinous processes were marked with radiopaque skin markers. Location of marker placement and presence of anatomical anomalies were determined by posteroanterior lumbar radiographs. Accuracy of marker placement and interobserver reliability were assessed using weighted κ values. Generalized linear mixed models and Cochran-Mantel-Haenszel tests assessed the relationship of accuracy to training level, presence of anatomical anomalies, and participant characteristics.

Results: Examiners identified a spinous process in 91% of vertebral assessments. Correct identification of vertebral level occurred 69% of the time (κ = 0.81; 95% confidence interval, 0.79-0.83). Faculty examiners were significantly more accurate in identifying the correct vertebral level than the resident examiner (67%-78% vs 51%, P ≤ .03). The presence of 12th rib anomalies decreased accuracy for all examiners (P ≤ .05), reducing accuracy from 74% to 55%. Accuracy was higher in male participants than in female participants (P = .01). Obesity significantly decreased accuracy (P = .0003) at L3 (50% vs 73%) and L4 (44% vs 72%).

Conclusions: Identification of lumbar spinous processes using multiple landmarks was more accurate than previously reported values. However, accuracy was dependent on examiner experience, presence of anatomical anomalies, and participant characteristics.

PubMed Disclaimer

Publication types

LinkOut - more resources