. 2011 Nov-Dec;10(6):508-13.
doi: 10.1016/j.brachy.2011.04.002. Epub 2011 Jun 2.

Cesium-131 permanent seed brachytherapy: dosimetric evaluation and radiation exposure to surgeons, radiation oncologists, and staff

Affiliations

Cesium-131 permanent seed brachytherapy: dosimetric evaluation and radiation exposure to surgeons, radiation oncologists, and staff

Bhupesh Parashar et al. Brachytherapy. 2011 Nov-Dec.

Abstract

Purpose: Cesium-131 ((131)Cs) radioactive seed is Food and Drug Administration approved for permanent seed implant for all cancers, including lung and head and neck (HN) cancers. We describe the first clinical report of (131)Cs dosimetry and exposure rates to treating physicians and staff.

Methods and materials: Twenty-eight patients received (131)Cs implant for early stage lung and recurrent HN cancers. A nomogram was developed to calculate the number of seeds needed to cover the wedge line with the prescription dose (80 Gy). Final dosimetry was obtained after CT planning a few days following the surgical procedure. Radiation exposure to the treating physicians and staff was measured at the completion of the procedure.

Results: A nomogram was developed using the variseed software with source data from American Association of Physicists in Medicine TG-43 report. The total volume covered by the prescription isodose line of (131)Cs was measured and compared with (125)I. The prescription volume was smaller for (131)Cs. In addition, the exposure rate with (131)Cs was found to be acceptable.

Conclusion: Our preliminary experience with (131)Cs lung and HN brachytherapy has been very encouraging with excellent dosimetric coverage and acceptable exposure to the treating physicians and staff.