. 2011 Jul 1;879(21):1954-60.
doi: 10.1016/j.jchromb.2011.05.027. Epub 2011 May 27.

Analyte and internal standard cross signal contributions and their impact on quantitation in LC-MS based bioanalysis

Affiliations

Analyte and internal standard cross signal contributions and their impact on quantitation in LC-MS based bioanalysis

Aimin Tan et al. J Chromatogr B Analyt Technol Biomed Life Sci. .

Abstract

Cross signal contributions between an analyte and its internal standard (IS) are very common due to impurities in reference standards and/or isotopic interferences. Despite the general awareness of this issue, how exactly they affect quantitation in LC-MS based bioanalysis has not been systematically evaluated. In this research, such evaluations were performed first by simulations and then by experiments using a typical bioanalytical method for tiagabine over the concentration range of 1-1000 ng/mL in human EDTA K(3) plasma. The results demonstrate that when an analyte contributes to IS signal, linearity and accuracy can be affected with low IS concentration. Thus, minimum IS concentrations have been obtained for different combinations of concentration range, percentage of cross contribution, and weighting factor. Moreover, while impurity in analyte reference standard is a factor in cross signal contribution, significant systematic errors could exist in the results of unknown samples even though the results of calibration standards and quality controls are acceptable. How these systematic errors would affect stability evaluation, method transfer, and cross validation has also been discussed and measures to reduce their impact are proposed. On the other hand, the signal contribution from an IS to the analyte causes shifting of a calibration curve, i.e. increase of intercept, and theoretically, the accuracy is not affected. The simulation results are well supported by experimental results. For example, good inter-run (between-run) accuracy (bias: -2.70 to 5.35%) and precision (CV: 2.07-10.50%) were obtained when runs were extracted with an IS solution containing 1-fold of the lower limit of quantitation.