Randomized Controlled Trial
. 2011 Jul;37(7):1282-90.
doi: 10.1016/j.jcrs.2011.01.029.

Corneal topography indices after corneal collagen crosslinking for keratoconus and corneal ectasia: one-year results

Affiliations
Randomized Controlled Trial

Corneal topography indices after corneal collagen crosslinking for keratoconus and corneal ectasia: one-year results

Steven A Greenstein et al. J Cataract Refract Surg. 2011 Jul.

Abstract

Purpose: To evaluate changes in corneal topography indices after corneal collagen crosslinking (CXL) in patients with keratoconus and corneal ectasia and analyze associations of these changes with visual acuity.

Setting: Cornea and refractive surgery subspecialty practice.

Design: Prospective randomized controlled clinical trial.

Methods: Corneal collagen crosslinking was performed in eyes with keratoconus or ectasia. Quantitative descriptors of corneal topography were measured with the Pentacam topographer and included 7 indices: index of surface variance, index of vertical asymmetry, keratoconus index, central keratoconus index, minimum radius of curvature, index of height asymmetry, and index of height decentration. Follow-up was 1 year.

Results: The study comprised 71 eyes, 49 with keratoconus and 22 with post-LASIK ectasia. In the entire patient cohort, there were significant improvements in the index of surface variance, index of vertical asymmetry, keratoconus index, and minimum radius of curvature at 1 year compared with baseline (all P < .001). There were no significant differences between the keratoconus and ectasia subgroups. Improvements in postoperative indices were not correlated with changes in corrected or uncorrected distance visual acuity.

Conclusions: There were improvements in 4 of 7 topography indices 1 year after CXL, suggesting an overall improvement in corneal shape. However, no significant correlation was found between the changes in individual topography indices and changes in visual acuity after CXL.