Detection of prosthetic mitral valve leak: a comparative study using transesophageal echocardiography, transthoracic echocardiography, and auscultation
- PMID: 2170454
- DOI: 10.1002/jcu.1870180706
Detection of prosthetic mitral valve leak: a comparative study using transesophageal echocardiography, transthoracic echocardiography, and auscultation
Abstract
Paravalvular leakage is a major complication of prosthetic valve dysfunction. Sixty-one subjects with valvular heart disease who had received prosthetic mitral valve replacement 5 months to 5 years before (43 received a porcine prosthesis and 18 received Bjork-Shiley valve prostheses) were evaluated for this complication. Careful auscultation was performed by two experienced cardiologists followed by transthoracic and transesophageal echocardiography. Physiologic leaks were detected in all Bjork-Shiley valves, but in only 30% of porcine valves using transesophageal echocardiography. These regurgitant jets were flame-like, with mean low velocities of 50 +/- 12.3 cm/sec and 48 +/- 18.2 cm/sec in the two types of valves. Neither transthoracic echocardiography nor auscultation could detect physiological regurgitant jets. Ten cases with paravalvular leak were detected by transesophageal echocardiography and subsequently demonstrated by left ventriculography (7 porcine, 3 Bjork-Shiley valves). Pathologic regurgitant jets were seen as high-velocity, systolic-retrograde turbulent flow across the prosthesis. However, only 6 cases of prosthetic valve dysfunction were detected by transthoracic echocardiography, 4 cases of mild paravalvular leakage went undetected. Thirteen of the 61 subjects had an apical systolic murmur and suspected prosthetic valve leakage; in 10 of the 13 cases the findings corresponded to those obtained by transesophageal echocardiography. In 3 cases of double valve replacement with Bjork-Shiley valves the magnitude of the leakage was overestimated by auscultation.
Similar articles
-
Variability of regurgitation in Björk-Shiley mitral valves and relationship to disc occluder design: an in vitro two-dimensional color-Doppler flow mapping study.J Heart Valve Dis. 1996 Aug;5 Suppl 2:S178-83. J Heart Valve Dis. 1996. PMID: 8905518
-
Transesophageal echocardiographic features of normal and dysfunctioning bioprosthetic valves.Am Heart J. 1991 Apr;121(4 Pt 1):1149-55. doi: 10.1016/0002-8703(91)90676-9. Am Heart J. 1991. PMID: 2008838
-
Regurgitant flow in apparently normal valve prostheses: improved detection and semiquantitative analysis by transesophageal two-dimensional color-coded Doppler echocardiography.J Am Soc Echocardiogr. 1990 May-Jun;3(3):187-95. doi: 10.1016/s0894-7317(14)80433-1. J Am Soc Echocardiogr. 1990. PMID: 2372401
-
Echocardiographic evaluation of prosthetic heart valves.Curr Cardiol Rep. 2015 Jun;17(6):48. doi: 10.1007/s11886-015-0602-z. Curr Cardiol Rep. 2015. PMID: 26003146 Review.
-
Echocardiographic assessment of prosthetic heart valves.Prog Cardiovasc Dis. 2014 Jul-Aug;57(1):100-10. doi: 10.1016/j.pcad.2014.05.001. Epub 2014 May 21. Prog Cardiovasc Dis. 2014. PMID: 25081405 Review.
Cited by
-
Real-time three-dimensional TEE guidance of a paravalvular mitral valve leak closure procedure.Herz. 2010 Jun;35(4):284-5. doi: 10.1007/s00059-011-3448-1. Epub 2011 Nov 17. Herz. 2010. PMID: 22086480 No abstract available.
-
Three-Plug Technique for Mitral Paravalvular Leak Closure in Marfan Syndrome.Cureus. 2025 Jan 24;17(1):e77920. doi: 10.7759/cureus.77920. eCollection 2025 Jan. Cureus. 2025. PMID: 39991344 Free PMC article.
-
Diagnostic evaluation of left-sided prosthetic heart valve dysfunction.Nat Rev Cardiol. 2011 May 17;8(8):466-78. doi: 10.1038/nrcardio.2011.71. Nat Rev Cardiol. 2011. PMID: 21587215 Review.
-
Percutaneous mitral and aortic paravalvular leak repair: indications, current application, and future directions.Curr Cardiol Rep. 2013 Mar;15(3):342. doi: 10.1007/s11886-012-0342-2. Curr Cardiol Rep. 2013. PMID: 23338724 Review.
-
Evaluation of hemolysis in patients with prosthetic heart valves.Clin Cardiol. 1998 Jun;21(6):387-92. doi: 10.1002/clc.4960210604. Clin Cardiol. 1998. PMID: 9631266 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources