Using a reduced spot size for intensity-modulated proton therapy potentially improves salivary gland-sparing in oropharyngeal cancer
- PMID: 21708427
- DOI: 10.1016/j.ijrobp.2011.05.005
Using a reduced spot size for intensity-modulated proton therapy potentially improves salivary gland-sparing in oropharyngeal cancer
Abstract
Purpose: To investigate whether intensity-modulated proton therapy with a reduced spot size (rsIMPT) could further reduce the parotid and submandibular gland dose compared with previously calculated IMPT plans with a larger spot size. In addition, it was investigated whether the obtained dose reductions would theoretically translate into a reduction of normal tissue complication probabilities (NTCPs).
Methods: Ten patients with N0 oropharyngeal cancer were included in a comparative treatment planning study. Both IMPT plans delivered simultaneously 70 Gy to the boost planning target volume (PTV) and 54 Gy to the elective nodal PTV. IMPT and rsIMPT used identical three-field beam arrangements. In the IMPT plans, the parotid and submandibular salivary glands were spared as much as possible. rsIMPT plans used identical dose-volume objectives for the parotid glands as those used by the IMPT plans, whereas the objectives for the submandibular glands were tightened further. NTCPs were calculated for salivary dysfunction and xerostomia.
Results: Target coverage was similar for both IMPT techniques, whereas rsIMPT clearly improved target conformity. The mean doses in the parotid glands and submandibular glands were significantly lower for three-field rsIMPT (14.7 Gy and 46.9 Gy, respectively) than for three-field IMPT (16.8 Gy and 54.6 Gy, respectively). Hence, rsIMPT significantly reduced the NTCP of patient-rated xerostomia and parotid and contralateral submandibular salivary flow dysfunction (27%, 17%, and 43% respectively) compared with IMPT (39%, 20%, and 79%, respectively). In addition, mean dose values in the sublingual glands, the soft palate and oral cavity were also decreased. Obtained dose and NTCP reductions varied per patient.
Conclusions: rsIMPT improved sparing of the salivary glands and reduced NTCP for xerostomia and parotid and submandibular salivary dysfunction, while maintaining similar target coverage results. It is expected that rsIMPT improves quality of life during and after radiotherapy treatment.
Copyright © 2012 Elsevier Inc. All rights reserved.
Similar articles
-
Potential benefits of scanned intensity-modulated proton therapy versus advanced photon therapy with regard to sparing of the salivary glands in oropharyngeal cancer.Int J Radiat Oncol Biol Phys. 2011 Mar 15;79(4):1216-24. doi: 10.1016/j.ijrobp.2010.05.012. Epub 2010 Aug 21. Int J Radiat Oncol Biol Phys. 2011. PMID: 20732761
-
Impact of salivary gland dosimetry on post-IMRT recovery of saliva output and xerostomia grade for head-and-neck cancer patients treated with or without contralateral submandibular gland sparing: a longitudinal study.Int J Radiat Oncol Biol Phys. 2011 Dec 1;81(5):1479-87. doi: 10.1016/j.ijrobp.2010.07.1990. Epub 2010 Oct 8. Int J Radiat Oncol Biol Phys. 2011. PMID: 20934262
-
The potential of intensity-modulated proton radiotherapy to reduce swallowing dysfunction in the treatment of head and neck cancer: A planning comparative study.Acta Oncol. 2013 Apr;52(3):561-9. doi: 10.3109/0284186X.2012.692885. Epub 2012 Jun 19. Acta Oncol. 2013. PMID: 22708528
-
Intensity-modulated radiotherapy: is xerostomia still prevalent?Curr Oncol Rep. 2005 Mar;7(2):131-6. doi: 10.1007/s11912-005-0039-4. Curr Oncol Rep. 2005. PMID: 15717947 Review.
-
Prospective investigation and literature review of tolerance dose on salivary glands using quantitative salivary gland scintigraphy in the intensity-modulated radiotherapy era.Head Neck. 2016 Apr;38 Suppl 1:E1746-55. doi: 10.1002/hed.24310. Epub 2016 Feb 15. Head Neck. 2016. PMID: 26875880 Review.
Cited by
-
Proton Beam Radiation Therapy for Oropharyngeal Squamous Cell Carcinoma.Int J Part Ther. 2023 Apr 27;9(4):243-252. doi: 10.14338/IJPT-22-00030.1. eCollection 2023 Spring. Int J Part Ther. 2023. PMID: 37169005 Free PMC article. Review.
-
Toward improved target conformity for two spot scanning proton therapy delivery systems using dynamic collimation.Med Phys. 2016 Mar;43(3):1421-7. doi: 10.1118/1.4942375. Med Phys. 2016. PMID: 26936726 Free PMC article.
-
PETRA: A pencil beam trimming algorithm for analytical proton therapy dose calculations with the dynamic collimation system.Med Phys. 2023 Nov;50(11):7263-7280. doi: 10.1002/mp.16559. Epub 2023 Jun 27. Med Phys. 2023. PMID: 37370239 Free PMC article.
-
Synchrotron-Based Pencil Beam Scanning Nozzle with an Integrated Mini-Ridge Filter: A Dosimetric Study to Optimize Treatment Delivery.Cancers (Basel). 2017 Dec 13;9(12):170. doi: 10.3390/cancers9120170. Cancers (Basel). 2017. PMID: 29236051 Free PMC article.
-
Quantification of beam size impact on intensity-modulated proton therapy with robust optimization in head and neck cancer-comparison with intensity-modulated radiation therapy.J Radiat Res. 2025 Jan 22;66(1):65-73. doi: 10.1093/jrr/rrae097. J Radiat Res. 2025. PMID: 39724929 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources