Utility of absolute and relative changes in cardiac troponin concentrations in the early diagnosis of acute myocardial infarction
- PMID: 21709058
- DOI: 10.1161/CIRCULATIONAHA.111.023937
Utility of absolute and relative changes in cardiac troponin concentrations in the early diagnosis of acute myocardial infarction
Abstract
Background: Current guidelines for the diagnosis of acute myocardial infarction (AMI), among other criteria, also require a rise and/or fall in cardiac troponin (cTn) levels. It is unknown whether absolute or relative changes in cTn have higher diagnostic accuracy and should therefore be preferred.
Methods and results: In a prospective, observational, multicenter study, we analyzed the diagnostic accuracy of absolute (Δ) and relative (Δ%) changes in cTn in 836 patients presenting to the emergency department with symptoms suggestive of AMI. Blood samples for the determination of high-sensitive cTn T and cTn I ultra were collected at presentation and after 1 and 2 hours in a blinded fashion. The final diagnosis was adjudicated by 2 independent cardiologists. The area under the receiver operating characteristic curve for diagnosing AMI was significantly higher for 2-hour absolute (Δ) versus 2-hour relative (Δ%) cTn changes (area under the receiver operating characteristic curve [95% confidence interval], high-sensitivity cTn T: 0.95 [0.92 to 0.98] versus 0.76 [0.70 to 0.83], P<0.001; cTn I ultra: 0.95 [0.91 to 0.99] versus 0.72 [0.66 to 0.79], P<0.001). The receiver operating characteristic curve-derived cutoff value for 2-hour absolute (Δ) change was 0.007 μg/L for high-sensitivity cTn T and 0.020 μg/L for cTn I ultra (both cutoff levels are half of the 99th percentile of the respective cTn assay). Absolute changes were superior to relative changes in patients with both low and elevated baseline cTn levels.
Conclusions: Absolute changes of cTn levels have a significantly higher diagnostic accuracy for AMI than relative changes, and seem therefore to be the preferred criteria to distinguish AMI from other causes of cTn elevations.
Clinical trial registration: URL: http://www.clinicaltrials.gov. UNIQUE IDENTIFIER: NCT00470587.
Comment in
-
Edging closer to early optimal patient management with high-sensitivity cardiac troponin assay.Circulation. 2011 Jul 12;124(2):127-9. doi: 10.1161/CIRCULATIONAHA.111.038851. Circulation. 2011. PMID: 21747063 No abstract available.
-
Letter by Kavsak and MacRae regarding article, "Utility of absolute and relative changes in cardiac troponin concentrations in the early diagnosis of acute myocardial infarction".Circulation. 2012 Feb 14;125(6):e358; author reply e359. doi: 10.1161/CIRCULATIONAHA.111.057885. Circulation. 2012. PMID: 22331927 No abstract available.
-
Is it more accurate to measure the absolute or the relative change of new high or ultrasensitive troponin assays to diagnose acute myocardial infarction?CJEM. 2014 Jul;16(4):323-6. doi: 10.2310/8000.2013.131109. CJEM. 2014. PMID: 25060087
Publication types
MeSH terms
Substances
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
