Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2012 Feb;19(2):577-83.
doi: 10.1245/s10434-011-1870-5. Epub 2011 Jun 28.

A meta-analysis of preoperative localization techniques for patients with primary hyperparathyroidism

Affiliations
Meta-Analysis

A meta-analysis of preoperative localization techniques for patients with primary hyperparathyroidism

Kevin Cheung et al. Ann Surg Oncol. 2012 Feb.

Abstract

Background: Reported accuracy of preoperative localization imaging for primary hyperparathyroidism (pHPT) varies. The purpose of this study is to determine the accuracy of ultrasound, sestamibi-single photon emission computed tomography (SPECT), and four-dimensional computed tomography (4D-CT) as preoperative localization strategies.

Methods: A meta-analysis was performed of studies investigating the accuracy of ultrasound, sestamibi-SPECT, and 4D-CT for preoperative localization in pHPT. Electronic databases were systematically searched, and two independent reviewers reviewed results using specific criteria. Study quality was assessed using a validated measure for diagnostic imaging studies. Study heterogeneity and pooled results were calculated.

Results: 43 studies met criteria for inclusion, and data were available for extraction in 19 ultrasound, 9 sestamibi-SPECT, and 4 4D-CT studies. Ultrasound had pooled sensitivity and positive predictive value (PPV) of 76.1% (95% CI 70.4-81.4%) and 93.2% (90.7-95.3%), respectively. Sestamibi-SPECT had pooled sensitivity and PPV of 78.9% (64-90.6%) and 90.7% (83.5-96.0%), respectively. Only two 4D-CT studies investigated patients undergoing initial parathyroidectomy. Results suggested sensitivity and PPV of 89.4% and 93.5%, respectively.

Conclusions: Ultrasound and sestamibi-SPECT are similar in ability to preoperatively localize abnormal parathyroid glands in pHPT. Accuracy may be improved with 4D-CT; however, further investigation is required. Choice of preoperative imaging strategy depends on numerous patient, institutional, and economic factors of which the surgeon must be aware.

PubMed Disclaimer

Publication types

MeSH terms

Substances

LinkOut - more resources