Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Aug;34(15):1796-804.
doi: 10.1002/jssc.201100117. Epub 2011 Jun 27.

Analysis of β-blockers in groundwater using large-volume injection coupled-column reversed-phase liquid chromatography with fluorescence detection and liquid chromatography time-of-flight mass spectrometry

Affiliations

Analysis of β-blockers in groundwater using large-volume injection coupled-column reversed-phase liquid chromatography with fluorescence detection and liquid chromatography time-of-flight mass spectrometry

María M Galera et al. J Sep Sci. 2011 Aug.

Abstract

Atenolol, nadolol, metoprolol, bisoprolol and betaxolol were simultaneously determined in groundwater samples by large-volume injection coupled-column reversed-phase liquid chromatography with fluorescence detection (LVI-LC-LC-FD) and liquid chromatography-time-of-flight mass spectrometry (LC-TOF-MS). The LVI-LC-LC-FD method combines analyte isolation, preconcentration and determination into a single step. Significant reductions in costs for sample pre-treatment (solvent and solid phases for clean up) and method development times are also achieved. Using LC-TOF-MS, accurate mass measurements within 3 ppm error were obtained for all of the β-blockers studied. Empirical formula information can be obtained by this method, allowing the unequivocal identification of the target compounds in the samples. To increase the sensitivity, a solid-phase extraction step with Oasis MCX cartridge was carried out yielding recoveries of 79-114% (n=5) with RSD 2-7% for the LC-TOF-MS method. SPE gives a high purification of β-blockers compared with the existing methods. A 100% methanol wash was allowed for these compounds with no loss of analytes. Limit of quantification was 1-7 ng/L for LVI-LC-LC-FD and 0.25-5 ng/L for LC-TOF-MS. As a result of selective extraction and effective removal of coextractives, no matrix effect was observed in LVI-LC-LC-FD and LC-TOF-MS analyses. The methods were applied to detect and quantify β-blockers in groundwater samples of Almería (Spain).

Keywords: Coupled columns; Groundwater; LC; TOF-MS; β-Blockers.

PubMed Disclaimer

Substances

LinkOut - more resources