Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2011 Oct;111(10):2451-9.
doi: 10.1007/s00421-011-2047-4. Epub 2011 Jun 30.

Transcutaneous neuromuscular electrical stimulation: influence of electrode positioning and stimulus amplitude settings on muscle response

Affiliations
Clinical Trial

Transcutaneous neuromuscular electrical stimulation: influence of electrode positioning and stimulus amplitude settings on muscle response

M Gobbo et al. Eur J Appl Physiol. 2011 Oct.

Abstract

The aim of the study was to investigate the influence of two different transcutaneous neuromuscular electrical stimulation procedures on evoked muscle torque and local tissue oxygenation. In the first one (MP mode), the cathode was facing the muscle main motor point and stimulus amplitude was set to the level eliciting the maximal myoelectrical activation according to the amplitude of the evoked electromyogram (EMG); in the second one (RC mode), the electrodes were positioned following common reference charts for electrode placement while stimulus amplitude was set according to subject tolerance. Tibialis Anterior (TA) and Vastus Lateralis (VL) muscles of 10 subjects (28.4 ± 8.2 years) were tested in specific dynamometers to measure the evoked isometric torque. The EMG and near-infrared spectroscopy probes were placed on muscle belly to detect the electrical activity and local metabolic modifications of the stimulated muscle, respectively. The stimulation protocol consisted of a gradually increasing frequency ramp from 2 to 50 Hz in 7.5 s. Compared to RC mode, in MP mode the contractile parameters (peak twitch, tetanic torque, area under the torque build-up) and the metabolic solicitation (oxygen consumption and hyperemia due to metabolites accumulation) resulted significantly higher for both TA and VL muscles. MP mode resulted also to be more comfortable for the subjects. Based on the assumption that proper mechanical and metabolic stimuli are necessary to induce muscle strengthening, our results witness the importance of an optimized, i.e., comfortable and effective, stimulation to promote the aforementioned muscle adaptive modifications.

PubMed Disclaimer

References

    1. J Appl Physiol (1985). 1990 Apr;68(4):1657-67 - PubMed
    1. Phys Ther. 1985 Feb;65(2):186-96 - PubMed
    1. Eur J Appl Physiol. 2010 Sep;110(2):223-34 - PubMed
    1. Sports Med. 1992 May;13(5):320-36 - PubMed
    1. J Rheumatol. 2003 Jul;30(7):1571-8 - PubMed

Publication types

MeSH terms

LinkOut - more resources