Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2011 Jul 7;34(7):e282-6.
doi: 10.3928/01477447-20110526-10.

Long-term results of dorsally displaced distal radius fractures treated with the pi-plate: is hardware removal necessary?

Affiliations
Clinical Trial

Long-term results of dorsally displaced distal radius fractures treated with the pi-plate: is hardware removal necessary?

Minos E Tyllianakis et al. Orthopedics. .

Abstract

The purpose of this study was to evaluate the outcome of patients treated with open reduction and internal fixation (ORIF) using dorsal plates and screws (AO/ASIF pi-plate) for dorsally displaced fractures of the distal radius. Although extensor tendon rupture is a recognized complication of all distal radial fractures, there appears to be an increased risk of this using dorsal plating. In addition, there is the added complication of extensor tendon irritation and dorsal wrist pain, which may necessitate plate removal. The low-profile pi-plates intended to overcome this problem have not done so, with quoted rates ranged from 19% to 55%.We treated 32 completely evaluated patients (13 men and 19 women) in our department between 2000 and 2004, with an average age of 46 years. They underwent ORIF of dorsally displaced fractures of the distal radius using the specially designed pi-plate. Bone graft was used in 18 patients who had significant metaphyseal defect. Clinical examination, plain radiographs, and functional assessments using the modified Mayo Wrist Score were performed at an average follow-up of 86 months (range, 56-115 months). Satisfactory reduction was achieved in all 32 fractures at the time of operative fixation with no instances of loss of fracture reduction during the study period. According to the Mayo Wrist Score, 23 patients (72%) had excellent or very good results, 7 (22%) had fair results, and 2 (6%) had poor results. Two cases (6.25%) of extensor tendon rupture were noted during the first postoperative month, and 2 other patients showed progressive weakness of index finger extension 6 months postoperatively. The remaining 28 patients had no soft tissue problems.

PubMed Disclaimer

Publication types

LinkOut - more resources