Probabilistic 4D blood flow tracking and uncertainty estimation
- PMID: 21719342
- DOI: 10.1016/j.media.2011.06.002
Probabilistic 4D blood flow tracking and uncertainty estimation
Abstract
Phase-Contrast (PC) MRI utilizes signal phase shifts resulting from moving spins to measure tissue motion and blood flow. Time-resolved 4D vector fields representing the motion or flow can be derived from the acquired PC MRI images. In cardiovascular PC MRI applications, visualization techniques such as vector glyphs, streamlines, and particle traces are commonly employed for depicting the blood flow. Whereas these techniques indeed provide useful diagnostic information, uncertainty due to noise in the PC-MRI measurements is ignored, which may lend the results a false sense of precision. In this work, the statistical properties of PC MRI flow measurements are investigated and a probabilistic flow tracking method based on sequential Monte Carlo sampling is devised to calculate flow uncertainty maps. The theoretical derivations are validated using simulated data and a number of real PC MRI data sets of the aorta and carotid arteries are used to demonstrate the flow uncertainty mapping technique.
Copyright © 2011 Elsevier B.V. All rights reserved.
Similar articles
-
Probabilistic 4D blood flow mapping.Med Image Comput Comput Assist Interv. 2010;13(Pt 3):416-23. doi: 10.1007/978-3-642-15711-0_52. Med Image Comput Comput Assist Interv. 2010. PMID: 20879427
-
4D phase contrast MRI at 3 T: effect of standard and blood-pool contrast agents on SNR, PC-MRA, and blood flow visualization.Magn Reson Med. 2010 Feb;63(2):330-8. doi: 10.1002/mrm.22199. Magn Reson Med. 2010. PMID: 20024953
-
Peak velocity measurements in tortuous arteries with phase contrast magnetic resonance imaging: the effect of multidirectional velocity encoding.Invest Radiol. 2014 Apr;49(4):189-94. doi: 10.1097/RLI.0000000000000013. Invest Radiol. 2014. PMID: 24300842
-
Imaging of the thoracic aorta with time-resolved three-dimensional phase-contrast MRI: a review.Semin Thorac Cardiovasc Surg. 2008 Winter;20(4):358-64. doi: 10.1053/j.semtcvs.2008.11.013. Semin Thorac Cardiovasc Surg. 2008. PMID: 19251177 Review.
-
4D flow MRI.J Magn Reson Imaging. 2012 Nov;36(5):1015-36. doi: 10.1002/jmri.23632. J Magn Reson Imaging. 2012. PMID: 23090914 Review.
Cited by
-
On the Role and Effects of Uncertainties in Cardiovascular in silico Analyses.Front Med Technol. 2021 Dec 1;3:748908. doi: 10.3389/fmedt.2021.748908. eCollection 2021. Front Med Technol. 2021. PMID: 35047960 Free PMC article.
-
Uncertainty Quantification in a Patient-Specific One-Dimensional Arterial Network Model: EnKF-Based Inflow Estimator.J Verif Valid Uncertain Quantif. 2017 Mar;2(1):0110021-1100214. doi: 10.1115/1.4035918. Epub 2017 Feb 22. J Verif Valid Uncertain Quantif. 2017. PMID: 35832352 Free PMC article.
-
Automatic 4D Flow MRI Segmentation Using the Standardized Difference of Means Velocity.IEEE Trans Med Imaging. 2023 Aug;42(8):2360-2373. doi: 10.1109/TMI.2023.3251734. Epub 2023 Aug 1. IEEE Trans Med Imaging. 2023. PMID: 37028010 Free PMC article.
-
Divergence-Free Constrained Phase Unwrapping and Denoising for 4D Flow MRI Using Weighted Least-Squares.IEEE Trans Med Imaging. 2021 Dec;40(12):3389-3399. doi: 10.1109/TMI.2021.3086331. Epub 2021 Nov 30. IEEE Trans Med Imaging. 2021. PMID: 34086567 Free PMC article.
-
Caval to pulmonary 3D flow distribution in patients with Fontan circulation and impact of potential 4D flow MRI error sources.Magn Reson Med. 2019 Feb;81(2):1205-1218. doi: 10.1002/mrm.27455. Epub 2018 Sep 15. Magn Reson Med. 2019. PMID: 30277276 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources