Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2011 Aug 31;371(1-2):81-90.
doi: 10.1016/j.jim.2011.06.016. Epub 2011 Jun 24.

Screening and characterization of new monoclonal anti-benzo[a]pyrene antibodies using automated flow-through microarray technology

Affiliations
Comparative Study

Screening and characterization of new monoclonal anti-benzo[a]pyrene antibodies using automated flow-through microarray technology

Xaver Y Z Karsunke et al. J Immunol Methods. .

Abstract

Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous environmental pollutants, which can cause cancer in humans. The maximum tolerable limit of benzo[a]pyrene (B[a]P) in drinking water was set to 10 ng/L by the European Commission (Council Directive 98/83/EC), because of its highly carcinogenic and mutagenic effect on humans. In the present investigation, mice were immunized with B[a]P-bovine serum albumin conjugates and 110 generated hybridoma cell lines screened by different techniques to identify clones that produce anti-B[a]P antibodies. Subsequently, a new automated flow-through biochip noncompetitive direct chemiluminescence immunoassay (CLEIA) was compared with conventional indirect and direct enzyme-linked immunosorbent assays (ELISAs). It was demonstrated that the microchip-based screening method compared to ELISA was fast and very sensitive with use of only nanoliter volumes of supernatant. Forty clones could be evaluated in less than 5 min. Six high affinity monoclonal antibodies with different cross-reactivities (CR) for individual PAHs were identified by the chip-based assay and indirect microtiter plate ELISA. In comparison, the direct ELISA in the microtiter plate failed to identify three of these clones. The four antibodies with the highest affinity had half maximum inhibitory concentrations (IC(50) values) between 0.31 and 0.92 μg/L for B[a]P. Affinity constants of these four antibodies were determined by surface plasmon resonance using a water soluble B[a]P-peptide. The observed CR pattern of the four monoclonal antibodies for 16 tested PAHs was quite different. Only one specific antibody for B[a]P was observed, while others were more suitable for class-specific PAH determination.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources