Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Aug;10(4):307-15.
doi: 10.7785/tcrt.2012.500207.

Feasibility of non-coplanar tomotherapy for lung cancer stereotactic body radiation therapy

Affiliations
Free article

Feasibility of non-coplanar tomotherapy for lung cancer stereotactic body radiation therapy

Wensha Yang et al. Technol Cancer Res Treat. 2011 Aug.
Free article

Abstract

To quantify the dosimetric gains from non-coplanar helical tomotherapy (HT) arcs for stereotactic body radiation therapy (SBRT) of lung cancer, we created oblique helical arcs by rotating patient's CT images. Ten, 20 and 30 degrees of yaws were introduced in the treatment planning for a patient with a hypothetical lung tumor at the upper, middle and lower portion of the right lung, and the upper and middle left lung. The planning target volume (PTV) was 43 cm(3). 60 Gy was prescribed to the PTV. Dose to organs at risk (OARs), which included the lungs, heart, spinal cord and chest wall, was optimized using a 2.5 cm jaw, 0.287 pitch and modulation factor of 2.5. Composite plans were generated by dose summation of the resultant plans. These plans were evaluated for its conformity index (R(x)) and percentile volume of lung receiving radiation dose of x Gy (V(x)). Conformity index was defined by the ratio of x percent isodose volume and PTV. The results show that combination of non-coplanar arcs reduced R(50) by 4.5%, R(20) by 26% and R(10) by 30% on average. Non-coplanar arcs did not affect V(20) but reduced V(10) and V(5) by 10% and 24% respectively. Composite of the non-coplanar arcs also reduced maximum dose to the spinal cord by 20-39%. Volume of chest wall receiving higher than 30 Gy was reduced by 48% on average. Heart dose reduction was dependent on the location of the PTV and the choice of non-coplanar orientations. Therefore we conclude that non-coplanar HT arcs significantly improve critical organ sparing in lung SBRT without changing the PTV dose coverage.

PubMed Disclaimer

MeSH terms

LinkOut - more resources