Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials?
- PMID: 21732057
- DOI: 10.1007/s00167-011-1588-8
Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials?
Abstract
Purpose: Computer-assisted surgery has been proposed as a technique to improve implant alignment during total knee arthroplasty (TKA). However, there is still a debate over the accuracy of placing the femoral and tibial components using computer-assisted systems in TKA. The aim of this study is to establish whether computer-assisted surgery leads to superior mechanical leg axis and implant positioning than conventional technique in patients with primary TKA.
Methods: Major electronic databases were systematically searched to identify relevant studies without language restriction. A meta-analysis of 41 randomized controlled trials (RCTs) or quasi-RCTs was performed in a random effects model. A subgroup analysis was conducted by type of navigation system to explore the clinical heterogeneity between these trials. The following radiographic parameters were used to compare computer-assisted surgery with conventional technique: (1) mechanical leg axis, (2) femoral component coronal alignment, (3) tibial component coronal alignment, (4) femoral component sagittal alignment, and (5) tibial component sagittal alignment.
Results: For the mechanical leg axis and coronal positioning of femoral and tibial components, there are statistically significant reductions in the number of patients with malalignment in the CAS group if the outlier cutoff value is ±3 or 2° in the coronal and sagittal planes, respectively. Subgroup analysis demonstrates that CT-free navigation systems provide better alignment than conventional techniques in the coronal and sagittal alignment of femoral components within ±3 and 2°. If the outlier cutoff value for the tibial sagittal alignment is ±2°, the outlier percentages are higher in the CT-free navigation group than in the conventional group. However, there was no significant difference in the tibial sagittal alignment at ±3°.
Conclusion: Computer-assisted surgery does improve mechanical leg axis and component orientation in TKAs. However, high-quality RCTs are necessary to determine whether surgeons could use computer-assisted techniques to achieve a targeted tibial slope in TKA.
Level of evidence: Therapeutic study (Systematic review of Level I/II studies), Level II.
Similar articles
-
Are There Differences in Accuracy or Outcomes Scores Among Navigated, Robotic, Patient-specific Instruments or Standard Cutting Guides in TKA? A Network Meta-analysis.Clin Orthop Relat Res. 2020 Sep;478(9):2105-2116. doi: 10.1097/CORR.0000000000001324. Clin Orthop Relat Res. 2020. PMID: 32530896 Free PMC article.
-
Favourable alignment outcomes with MRI-based patient-specific instruments in total knee arthroplasty.Knee Surg Sports Traumatol Arthrosc. 2018 Sep;26(9):2659-2668. doi: 10.1007/s00167-017-4637-0. Epub 2017 Jul 11. Knee Surg Sports Traumatol Arthrosc. 2018. PMID: 28698929
-
Robotic-assisted total knee arthroplasty is more advantageous for knees with severe deformity: a randomized controlled trial study design.Int J Surg. 2023 Mar 1;109(3):287-296. doi: 10.1097/JS9.0000000000000002. Int J Surg. 2023. PMID: 36927832 Free PMC article. Clinical Trial.
-
Current state of computer navigation and robotics in unicompartmental and total knee arthroplasty: a systematic review with meta-analysis.Knee Surg Sports Traumatol Arthrosc. 2016 Nov;24(11):3482-3495. doi: 10.1007/s00167-016-4305-9. Epub 2016 Sep 6. Knee Surg Sports Traumatol Arthrosc. 2016. PMID: 27600634
-
Accuracy of MRI-based vs. CT-based patient-specific instrumentation in total knee arthroplasty: A meta-analysis.J Orthop Sci. 2017 Jan;22(1):116-120. doi: 10.1016/j.jos.2016.10.007. Epub 2016 Nov 4. J Orthop Sci. 2017. PMID: 27823847
Cited by
-
No difference between computer-assisted and conventional total knee arthroplasty: five-year results of a prospective randomised study.Knee Surg Sports Traumatol Arthrosc. 2013 Oct;21(10):2241-7. doi: 10.1007/s00167-013-2608-7. Epub 2013 Jul 14. Knee Surg Sports Traumatol Arthrosc. 2013. PMID: 23851969 Clinical Trial.
-
Less outliers in pinless navigation compared with conventional surgery in total knee arthroplasty.Knee Surg Sports Traumatol Arthrosc. 2014 Aug;22(8):1827-32. doi: 10.1007/s00167-013-2456-5. Epub 2013 Mar 2. Knee Surg Sports Traumatol Arthrosc. 2014. PMID: 23455388
-
CT-based patient-specific instrumentation for total knee arthroplasty in over 700 cases: single-use instruments are as accurate as standard instruments.Knee Surg Sports Traumatol Arthrosc. 2022 Feb;30(2):447-455. doi: 10.1007/s00167-020-06150-x. Epub 2020 Jul 16. Knee Surg Sports Traumatol Arthrosc. 2022. PMID: 32676744 Free PMC article.
-
Application of computer-assisted navigation in mandibular angle osteotomy.J Int Med Res. 2019 Jul;47(7):3160-3170. doi: 10.1177/0300060519850722. Epub 2019 Jun 17. J Int Med Res. 2019. PMID: 31204540 Free PMC article.
-
Accuracies of bone resection, implant position, and limb alignment in robotic-arm-assisted total knee arthroplasty: a prospective single-centre study.J Orthop Surg Res. 2022 Jan 29;17(1):61. doi: 10.1186/s13018-022-02957-1. J Orthop Surg Res. 2022. PMID: 35093133 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials