External validation of exhaled breath profiling using an electronic nose in the discrimination of asthma with fixed airways obstruction and chronic obstructive pulmonary disease
- PMID: 21732998
- DOI: 10.1111/j.1365-2222.2011.03800.x
External validation of exhaled breath profiling using an electronic nose in the discrimination of asthma with fixed airways obstruction and chronic obstructive pulmonary disease
Abstract
Background: Fixed airflow limitation can be found both in asthma and chronic obstructive pulmonary disease (COPD), posing a day-to-day diagnostic challenge.
Objective: We aimed to determine the external validity of metabolomic analysis of exhaled air by electronic nose for distinguishing asthma and COPD in patients with fixed airways obstruction.
Methods: One hundred patients were included in a cross-sectional design: 60 asthma patients: 21 with fixed airways obstruction (fixed asthma), 39 with reversible airways obstruction (classic asthma) and 40 COPD patients (GOLD stages II-III). Standardized sampling of exhaled breath was performed and volatile organic compounds were captured using an electronic nose resulting in breathprints. External validity in newly recruited patients (validation sets) was tested using a previous and independent training set. Breathprints were analysed by principal component and canonical discriminant analysis and area under the curve (AUC) of receiver operating characteristic curves.
Results: External validity of breathprints showed 88% accuracy for distinguishing fixed asthma from COPD (AUC 0.95, 95% CI 0.84-1.00, sensitivity 85%, specificity 90%) and 83% for classic asthma (AUC 0.93, 95% CI 0.87-1.00, sensitivity 91%, specificity 90%) (both P<0.001). Discriminative accuracy was not confounded by current smoking.
Conclusions and clinical relevance: External validation of exhaled breath molecular profiling shows high accuracy in distinguishing asthma and COPD in newly recruited patients with fixed airways obstruction. Exhaled air analysis may therefore reduce misdiagnosis in obstructive airways diseases, potentially leading to more appropriate management.
© 2011 Blackwell Publishing Ltd.
Similar articles
-
Exhaled breath profiling enables discrimination of chronic obstructive pulmonary disease and asthma.Am J Respir Crit Care Med. 2009 Dec 1;180(11):1076-82. doi: 10.1164/rccm.200906-0939OC. Epub 2009 Aug 27. Am J Respir Crit Care Med. 2009. PMID: 19713445
-
Discrimination between COPD patients with and without alpha 1-antitrypsin deficiency using an electronic nose.Respirology. 2011 Nov;16(8):1258-64. doi: 10.1111/j.1440-1843.2011.02047.x. Respirology. 2011. PMID: 21883674
-
Breath profiles by electronic nose correlate with systemic markers but not ozone response.Respir Med. 2011 Sep;105(9):1352-63. doi: 10.1016/j.rmed.2011.03.002. Epub 2011 Mar 24. Respir Med. 2011. PMID: 21439804 Clinical Trial.
-
Exhaled breath analysis by electronic nose in airways disease. Established issues and key questions.Clin Exp Allergy. 2013 Jul;43(7):705-15. doi: 10.1111/cea.12052. Clin Exp Allergy. 2013. PMID: 23786277 Review.
-
Exhaled breath condensate biomarkers in COPD.Eur Respir J. 2008 Aug;32(2):472-86. doi: 10.1183/09031936.00116107. Eur Respir J. 2008. PMID: 18669788 Review.
Cited by
-
Asthma in the elderly: a different disease?Breathe (Sheff). 2016 Mar;12(1):18-28. doi: 10.1183/20734735.002816. Breathe (Sheff). 2016. PMID: 27064568 Free PMC article. Review.
-
Pathophysiological Mechanisms of Asthma.Front Pediatr. 2019 Mar 19;7:68. doi: 10.3389/fped.2019.00068. eCollection 2019. Front Pediatr. 2019. PMID: 30941334 Free PMC article. Review.
-
Severe T2-high asthma in the biologics era: European experts' opinion.Eur Respir Rev. 2019 Jul 8;28(152):190054. doi: 10.1183/16000617.0054-2019. Print 2019 Jun 30. Eur Respir Rev. 2019. PMID: 31285291 Free PMC article. Review.
-
Biomarkers for the Phenotyping and Monitoring of Asthma in Children.Curr Treat Options Allergy. 2016;3(4):439-452. doi: 10.1007/s40521-016-0106-0. Epub 2016 Oct 20. Curr Treat Options Allergy. 2016. PMID: 27942431 Free PMC article. Review.
-
Significance of Exhaled Breath Test in Clinical Diagnosis: A Special Focus on the Detection of Diabetes Mellitus.J Med Biol Eng. 2016;36(5):605-624. doi: 10.1007/s40846-016-0164-6. Epub 2016 Oct 11. J Med Biol Eng. 2016. PMID: 27853412 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical