Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2011 Nov;66(11):1036-48.
doi: 10.1016/j.crad.2011.05.007. Epub 2011 Jul 6.

Diagnostic accuracy of ultrasound for rotator cuff tears in adults: a systematic review and meta-analysis

Affiliations
Meta-Analysis

Diagnostic accuracy of ultrasound for rotator cuff tears in adults: a systematic review and meta-analysis

T O Smith et al. Clin Radiol. 2011 Nov.

Abstract

Aim: To determine the diagnostic accuracy of ultrasound to detect partial and complete thickness rotator cuff tears based on all available clinical trials.

Materials and methods: An electronic search of databases registering published and unpublished literature was conducted. All diagnostic accuracy studies that directly compared the accuracy of ultrasound (the index test) to either arthroscopic or open surgical findings (the reference test) for rotator cuff tear were included. The methodological quality of each included study was assessed using the QUADAS form. When appropriate, pooled sensitivity and specificity analysis was conducted, with an assessment of the summary receiver operating characteristic (ROC) curve for each analysis.

Results: Sixty-two studies assessing 6007 patients and 6066 shoulders were included. Ultrasonography had good sensitivity and specificity for the assessment of partial thickness (sensitivity 0.84; specificity 0.89), and full-thickness rotator cuff tears (sensitivity 0.96; specificity 0.93). However, the literature poorly described population characteristics, assessor blinding, and was based on limited sample sizes. The literature assessing transducer frequency was particularly small in size.

Conclusion: Ultrasonography is an appropriate radiological technique for the assessment of rotator cuff tears with an acceptable sensitivity and specificity. The diagnostic test accuracy of ultrasound is superior for the detection of full-thickness compared to partial-thickness cuff tears. Further study assessing the effect of transducer frequency is warranted.

PubMed Disclaimer

LinkOut - more resources