Image quality and patient dose in computed tomography examinations in Greece
- PMID: 21743078
- DOI: 10.1093/rpd/ncr282
Image quality and patient dose in computed tomography examinations in Greece
Abstract
The purpose of this study is to evaluate image quality of various computed tomography (CT) scanners installed in Greece, as well as to investigate patient doses from common CT examinations. An image quality survey was performed in 44 CT scanners countrywide. The imaging performance of the systems was evaluated by measurements of certain parameters, such as image noise, spatial uniformity, high- and low-contrast resolution and slice thickness accuracy. Moreover, preliminary results of patient dose survey are presented. Concerning image quality, 80 % of the scanners were found to be in compliance with the national legislation and relative international guidelines for all the examined parameters. Weighted CT dose index and dose-length product values for chest and abdomen routine examinations were generally below the dose reference levels (DRLs) suggested by the European Commission. However, some scanners were found to deliver significantly higher doses than the suggested DRL for head routine examinations. Finally, differences in the performance among scanners of the same type and similar age were observed, pointing out the importance of frequent calibration, routine quality control and proper maintenance.
Similar articles
-
Quality control and patient doses in X-ray computed tomography.Radiat Prot Dosimetry. 2011 Sep;147(1-2):126-8. doi: 10.1093/rpd/ncr283. Epub 2011 Jul 9. Radiat Prot Dosimetry. 2011. PMID: 21743075
-
Performance evaluation of an 85-cm-bore X-ray computed tomography scanner designed for radiation oncology and comparison with current diagnostic CT scanners.Int J Radiat Oncol Biol Phys. 2002 Mar 15;52(4):1123-31. doi: 10.1016/s0360-3016(01)02779-1. Int J Radiat Oncol Biol Phys. 2002. PMID: 11958910
-
Diagnostic reference levels and patient doses in computed tomography examinations in Greece.Radiat Prot Dosimetry. 2015 Feb;163(3):319-24. doi: 10.1093/rpd/ncu182. Epub 2014 Jun 2. Radiat Prot Dosimetry. 2015. PMID: 24891405
-
CT radiation dose and image quality.Radiol Clin North Am. 2005 Nov;43(6):953-62, vii. doi: 10.1016/j.rcl.2005.07.002. Radiol Clin North Am. 2005. PMID: 16253656 Review.
-
Importance in optimization of multi-slice computed tomography scan protocols.Australas Radiol. 2006 Jun;50(3):278-85. doi: 10.1111/j.1440-1673.2006.01579.x. Australas Radiol. 2006. PMID: 16732832 Review.
MeSH terms
LinkOut - more resources
Full Text Sources