Method to reduce errors of droplet sizing based on the ratio of fluorescent and scattered light intensities (laser-induced fluorescence/Mie technique)
- PMID: 21743575
- DOI: 10.1364/AO.50.003622
Method to reduce errors of droplet sizing based on the ratio of fluorescent and scattered light intensities (laser-induced fluorescence/Mie technique)
Abstract
The droplet sizing accuracy of the laser technique, based on the ratio of laser-induced fluorescence (LIF) and scattered light (Mie) intensities from droplets, is examined. We develop an analytical model of the ratio of fluorescent to scattered light intensities of droplets, which shows that the LIF/Mie technique is susceptible to sizing errors that depend on the mean droplet size and the spread of the droplet size distribution. The sizing uncertainty due to the oscillations of the scattered light intensity as a function of droplet size is first quantified. Then, a new data processing method is proposed that can improve the sizing uncertainty of the technique for the sprays that were examined in this study by more than 5% by accounting for the size spread of the measured droplets, while improvements of 25% are possible when accounting for the mean droplet size. The sizing accuracy of the technique is evaluated in terms of the refractive index of liquid, scattering angle, and dye concentration in the liquid. It is found that the proposed approach leads to sizing uncertainty of less than 14% when combined with light collection at forward scattering angles close to 60° and the lowest fluorescent dye concentration in the liquid for all refractive indices.
© 2011 Optical Society of America
Similar articles
-
Numerical evaluation of droplet sizing based on the ratio of fluorescent and scattered light intensities (LIF/Mie technique).Appl Opt. 2011 Mar 20;50(9):1197-209. doi: 10.1364/AO.50.001197. Appl Opt. 2011. PMID: 21460991
-
Estimation of the droplet size spread with the laser induced fluorescence/Mie technique.Opt Lett. 2012 Jun 1;37(11):2040-2. doi: 10.1364/OL.37.002040. Opt Lett. 2012. PMID: 22660114
-
Analysis of LIF and Mie signals from single micrometric droplets for instantaneous droplet sizing in sprays.Opt Express. 2018 Nov 26;26(24):31750-31766. doi: 10.1364/OE.26.031750. Opt Express. 2018. PMID: 30650756
-
Experimental investigation of Gaussian beam effects on the accuracy of a droplet sizing method.Appl Opt. 1991 Nov 20;30(33):4930-5. doi: 10.1364/AO.30.004930. Appl Opt. 1991. PMID: 20717299
-
Fluorescence correlation spectroscopy for particle sizing: A notorious challenge.Biophys J. 2025 Mar 24:S0006-3495(25)00171-7. doi: 10.1016/j.bpj.2025.03.017. Online ahead of print. Biophys J. 2025. PMID: 40134216 Review.
Cited by
-
Characterization of Fluorescence Tracers for Thermometry and Film Thickness Measurements in Liquid Coolants Relevant for Thermal Management of Electric and Electronic Components.Sensors (Basel). 2022 Nov 17;22(22):8892. doi: 10.3390/s22228892. Sensors (Basel). 2022. PMID: 36433496 Free PMC article.
-
A Novel Approach for Measurement of Composition and Temperature of N-Decane/Butanol Blends Using Two-Color Laser-Induced Fluorescence of Nile Red.Sensors (Basel). 2020 Oct 8;20(19):5721. doi: 10.3390/s20195721. Sensors (Basel). 2020. PMID: 33050078 Free PMC article.
-
Fluorescence Spectroscopy for Studying Evaporating Droplets Using the Dye Eosin-Y.Sensors (Basel). 2020 Oct 22;20(21):5985. doi: 10.3390/s20215985. Sensors (Basel). 2020. PMID: 33105767 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources