Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Jul 4:(53):2896.
doi: 10.3791/2896.

Fluorescent nanoparticles for the measurement of ion concentration in biological systems

Affiliations

Fluorescent nanoparticles for the measurement of ion concentration in biological systems

J Matthew Dubach et al. J Vis Exp. .

Abstract

Tightly regulated ion homeostasis throughout the body is necessary for the prevention of such debilitating states as dehydration.(1) In contrast, rapid ion fluxes at the cellular level are required for initiating action potentials in excitable cells.(2) Sodium regulation plays an important role in both of these cases; however, no method currently exists for continuously monitoring sodium levels in vivo (3) and intracellular sodium probes (4) do not provide similar detailed results as calcium probes. In an effort to fill both of these voids, fluorescent nanosensors have been developed that can monitor sodium concentrations in vitro and in vivo.(5,6) These sensors are based on ion-selective optode technology and consist of plasticized polymeric particles in which sodium specific recognition elements, pH-sensitive fluorophores, and additives are embedded.(7-9) Mechanistically, the sodium recognition element extracts sodium into the sensor. (10) This extraction causes the pH-sensitive fluorophore to release a hydrogen ion to maintain charge neutrality within the sensor which causes a change in fluorescence. The sodium sensors are reversible and selective for sodium over potassium even at high intracellular concentrations.(6) They are approximately 120 nm in diameter and are coated with polyethylene glycol to impart biocompatibility. Using microinjection techniques, the sensors can be delivered into the cytoplasm of cells where they have been shown to monitor the temporal and spatial sodium dynamics of beating cardiac myocytes.(11) Additionally, they have also tracked real-time changes in sodium concentrations in vivo when injected subcutaneously into mice.(3) Herein, we explain in detail and demonstrate the methodology for fabricating fluorescent sodium nanosensors and briefly demonstrate the biological applications our lab uses the nanosensors for: the microinjection of the sensors into cells; and the subcutaneous injection of the sensors into mice.

PubMed Disclaimer

References

    1. Adrogue HJ, Madias NE. Hyponatremia. N Engl J Med. 2000;342:1581–1589. - PubMed
    1. Kim DY. BACE1 regulates voltage-gated sodium channels and neuronal activity. Nat Cell Biol. 2007;9:755–764. - PMC - PubMed
    1. Dubach JM, Lim E, Zhang N, Francis KP, Clark H. in vivo sodium concentration continuously monitored with fluorescent sensors. Integr Biol (Camb) 2010. - PubMed
    1. Minta A, Tsien RY. Fluorescent indicators for cytosolic sodium. J Biol Chem. 1989;264:19449–19457. - PubMed
    1. Dubach JM, Harjes DI, Clark HA. Ion-selective nano-optodes incorporating quantum dots. Journal of the American Chemical Society. 2007;129:8418–8418. - PubMed

Publication types