On the extraction of topologically correct thickness measurements using Khalimsky's cubic complex
- PMID: 21761654
- DOI: 10.1007/978-3-642-22092-0_14
On the extraction of topologically correct thickness measurements using Khalimsky's cubic complex
Abstract
The extraction of thickness measurements from shapes with spherical topology has been an active area of research in medical imaging. Measuring the thickness of structures from automatic probabilistic ume (PV) effects and the limited resolution of medical images. Also, the complexity of certain shapes, like the highly convoluted and PV ments. In this paper we explore the use of Khalimsky's cubic complex for the extraction of topologically correct thickness measurements from probabilistic or fuzzy segmentations without explicit parametrisation of the edge. A sequence of element collapse operations is used to correct the topology of the segmentation. The Laplace equation is then solved between multiple equipotential lines and the thickness measured with an ordered upwind differencing method using an anisotropic grid with the probabilistic segmentation as a speed function. Experiments performed on digital phantoms show that the proposed method obtains topologically correct thickness measurements with an increase in accuracy when compared to two well established techniques. Furthermore, quantitative analysis on brain MRI data showed that the proposed algorithm is able to retrieve expected group differences between the cortical thickness of AD patients and controls with high statistical significance.
Similar articles
-
Longitudinal cortical thickness estimation using Khalimsky's cubic complex.Med Image Comput Comput Assist Interv. 2011;14(Pt 2):467-75. doi: 10.1007/978-3-642-23629-7_57. Med Image Comput Comput Assist Interv. 2011. PMID: 21995062
-
A fast, model-independent method for cerebral cortical thickness estimation using MRI.Med Image Anal. 2009 Apr;13(2):269-85. doi: 10.1016/j.media.2008.10.006. Epub 2008 Nov 6. Med Image Anal. 2009. PMID: 19068276
-
Topology preserving tissue classification with fast marching and topology templates.Inf Process Med Imaging. 2005;19:234-45. doi: 10.1007/11505730_20. Inf Process Med Imaging. 2005. PMID: 17354699
-
Octree grid topology preserving geometric deformable model for three-dimensional medical image segmentation.Inf Process Med Imaging. 2007;20:556-68. doi: 10.1007/978-3-540-73273-0_46. Inf Process Med Imaging. 2007. PMID: 17633729
-
State of the art survey on MRI brain tumor segmentation.Magn Reson Imaging. 2013 Oct;31(8):1426-38. doi: 10.1016/j.mri.2013.05.002. Epub 2013 Jun 20. Magn Reson Imaging. 2013. PMID: 23790354 Review.
Cited by
-
Inference of Cerebrovascular Topology With Geodesic Minimum Spanning Trees.IEEE Trans Med Imaging. 2019 Jan;38(1):225-239. doi: 10.1109/TMI.2018.2860239. Epub 2018 Jul 26. IEEE Trans Med Imaging. 2019. PMID: 30059296 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Medical