Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2011 Oct;27(10):955-63.
doi: 10.1016/j.dental.2011.06.001. Epub 2011 Jul 16.

22-Year clinical evaluation of the performance of two posterior composites with different filler characteristics

Affiliations
Comparative Study

22-Year clinical evaluation of the performance of two posterior composites with different filler characteristics

Paulo A Da Rosa Rodolpho et al. Dent Mater. 2011 Oct.

Abstract

Objectives: This retrospective longitudinal study investigated the longevity of posterior restorations placed in a single general practice using 2 different composites in filler characteristics and material properties: P-50 APC (3M ESPE) with 70vol.% inorganic filler loading (midfilled) and Herculite XR (Kerr) with 55vol.% filler loading (minifilled).

Methods: Patient records were used for collecting data. Patients with at least 2 posterior composite restorations placed between 1986 and 1990, and still in the practice for regular check-up visits, were selected. 61 patients (20 male, 41 female, age 31.2-65.1) presenting 362 restorations (121 Class I, 241 Class II) placed using a closed sandwich technique were evaluated by 2 operators using the FDI criteria. Data were analyzed with Fisher's exact test, Kaplan-Meier statistics, and Cox regression analysis (p<0.05).

Results: 110 failures were detected. Similar survival rates for both composites were observed considering the full period of observation; better performance for the midfilled was detected considering the last 12 years. There was higher probability of failure in molars and for multi-surface restorations.

Significance: Both evaluated composites showed good clinical performance over 22 years with 1.5% (midfilled) and 2.2% (minifilled) annual failure rate. Superior longevity for the higher filler loaded composite (midfilled) was observed in the second part of the observation period with constant annual failure rate between 10 years and 20 years, whereas the minifilled material showed an increase in annual failure rate between 10 years and 20 years, suggesting that physical properties of the composite may have some impact on restoration longevity.