- PMID: 21764807
- DOI: 10.1093/rpd/ncr299
Radiation and cataract
Abstract
When this paper was about to go to press, the International Commission on Radiological Protection released a statement recommending a change in the threshold dose for the eye lens and dose limits for eye for occupationally exposed persons. It is clear that the earlier published threshold for radiation cataract is no longer valid. Epidemiological studies among Chernobyl clean-up workers, A bomb survivors, astronauts, residents of contaminated buildings, radiological technicians and recent surveys of staff in interventional rooms indicate that there is an increased incidence of lens opacities at doses below 1 Gy. Nevertheless, eye lens dosimetry is at a primitive stage and needs to be developed further. Despite uncertainties concerning dose threshold and dosimetry, it is possible to significantly reduce the risk of radiation cataract through the use of appropriate eye protection. By increasing awareness among those at risk and better adoption and increased usage of protective measures, radiation cataract can become preventable despite lowering of dose limits.
Similar articles
-
Epidemiological studies of cataract risk at low to moderate radiation doses: (not) seeing is believing.Radiat Res. 2010 Dec;174(6):889-94. doi: 10.1667/RR1884.1. Epub 2010 Aug 30. Radiat Res. 2010. PMID: 21128813 Review.
-
Radiation cataract.Ann ICRP. 2012 Oct-Dec;41(3-4):80-97. doi: 10.1016/j.icrp.2012.06.018. Epub 2012 Aug 22. Ann ICRP. 2012. PMID: 23089007
-
[Cataract: based on A-bomb survivor studies].Nihon Rinsho. 2012 Mar;70(3):441-5. Nihon Rinsho. 2012. PMID: 22514923 Japanese.
-
Deterministic Effects to the Lens of the Eye Following Ionizing Radiation Exposure: is There Evidence to Support a Reduction in Threshold Dose?Health Phys. 2018 Mar;114(3):328-343. doi: 10.1097/HP.0000000000000810. Health Phys. 2018. PMID: 29360710
-
An update on effects of ionizing radiation exposure on the eye.Br J Radiol. 2020 Nov 1;93(1115):20190829. doi: 10.1259/bjr.20190829. Epub 2019 Nov 12. Br J Radiol. 2020. PMID: 31670577 Free PMC article. Review.
Cited by
-
The radiation issue in cardiology: the time for action is now.Cardiovasc Ultrasound. 2011 Nov 21;9:35. doi: 10.1186/1476-7120-9-35. Cardiovasc Ultrasound. 2011. PMID: 22104562 Free PMC article.
-
The difference in ocular lens equivalent dose to ERCP personnel between prone and left lateral decubitus positions: a prospective randomized study.Endosc Int Open. 2018 Aug;6(8):E969-E974. doi: 10.1055/a-0599-5917. Epub 2018 Aug 1. Endosc Int Open. 2018. PMID: 30083586 Free PMC article.
-
A simple ergonomic measure reduces fluoroscopy time during ERCP: A multivariate analysis.Endosc Int Open. 2017 Mar;5(3):E172-E178. doi: 10.1055/s-0043-102934. Endosc Int Open. 2017. PMID: 28299352 Free PMC article.
-
Effect of ROI filtering in 3D cone-beam rotational angiography on organ dose and effective dose in cerebral investigations.J Appl Clin Med Phys. 2015 Mar 8;16(2):5306. doi: 10.1120/jacmp.v16i2.5306. J Appl Clin Med Phys. 2015. PMID: 26103200 Free PMC article.
-
Data analysis of low dose multislice helical CT scan in orbital trauma.Int J Ophthalmol. 2012;5(3):366-9. doi: 10.3980/j.issn.2222-3959.2012.03.22. Epub 2012 Jun 18. Int J Ophthalmol. 2012. PMID: 22773989 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical