Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Oct;95(10):1424-6.
doi: 10.1136/bjo.2010.201129. Epub 2011 Jul 18.

Subjective and functional deterioration in recurrences of neovascular AMD are often preceded by morphologic changes in optic coherence tomography

Affiliations

Subjective and functional deterioration in recurrences of neovascular AMD are often preceded by morphologic changes in optic coherence tomography

Robert Hoerster et al. Br J Ophthalmol. 2011 Oct.

Abstract

Background: Different tests were applied to test the sensitivity of patient self-control; Amsler grid and visual acuity (VA) assessment, as well as fundus examinations to reveal recurrent choroidal neovascularisation (CNV) activity in age-related macular degeneration as detected by spectral domain optical coherence tomography (SD-OCT) in monthly controls.

Methods: A prospective interventional case series of patients with exudative age-related macular degeneration was examined, which received ranibizumab injections until complete resolution of fluid in SD-OCT. Analysis of changes in subjective perception, Amsler grid, early treatment diabetic retinopathy study (ETDRS) VA, Radner reading VA and fundus examination was conducted in the case of OCT-confirmed CNV recurrences.

Results: Out of 40 morphological recurrences determined by SD-OCT, six (15%) were noticed by subjective patient perception. Amsler grid testing revealed deterioration in 12 cases (30%); 11 recurrences (28%) were accompanied by loss of ≥5 letters in ETDRS VA and/or ≥ 1 line in Radner VA; fundus examination showed signs of novel CNV activity in 10 out of 40 recurrences (25%). The combined sensitivity of all diagnostic methods compared to SD-OCT for recurrence detection was 67.5% (27 out of 40 recurrences).

Conclusion: Subjective patient perception, Amsler grid, VA as well as fundus examination lead to pronounced underestimations of CNV recurrences. Morphologic recurrences can be detected prior to functional deterioration. As any delay of treatment can result in irreversible vision loss, attempts should be made to provide monthly OCT controls to detect recurrences as early as possible.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources