Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Apr;112(4):1197-205.
doi: 10.1007/s00421-011-2076-z. Epub 2011 Jul 17.

The reliability of the intermittent critical velocity test and assessment of critical rest interval in men and women

Affiliations

The reliability of the intermittent critical velocity test and assessment of critical rest interval in men and women

David H Fukuda et al. Eur J Appl Physiol. 2012 Apr.

Abstract

The purpose of this study was to examine the reliability of the intermittent critical velocity (ICV) test and assess critical rest interval (CRI) during repeated-sprint exercise. The ICV test is used to examine the linear relationship between total distance and time-to-exhaustion during interval exercise, yielding a repeatable, moderate-intensity parameter (ICV), a high-intensity exhaustive parameter (W'), and CRI. CRI is the theoretical rest period needed to complete a series of repeated bouts of exercise without fatigue. Twenty-four healthy college-aged men (mean ± SD; age 22.7 ± 2.9 years; weight 85.8 ± 15.3 kg; VO(2max) 50.7 ± 8.8 ml/kg/min) and women (mean ± SD; age 21.4 ± 2.3 years; weight 58.9 ± 5.2 kg; VO(2max) 46.4 ± 4.4 ml/kg/min) participants completed two ICV tests (T1 and T2), using 10 s repeated sprints to exhaustion during separate sessions of treadmill running. Linear regression was used to determine ICV and W', while CRI was calculated using the relationship between the number of intervals completed and a variant of ICV. Intraclass correlation coefficients (ICCs) for ICV, W', and CRI were 0.89 (T1 4.42 ± 0.55 m/s; T2 4.34 ± 0.67 m/s), 0.80 (T1 125.6 ± 62.7 m; T2 144.6 ± 65.4 m), and 0.59 (T1 23.9 ± 2.0 s; T2 24.5 ± 2.6 s), respectively. These moderate to high ICC values indicate reliable measurements between ICV trials. Additionally, the evaluation of CRI demonstrated the attainment of a steady-state heart rate (94% of maximum) during a separate session of repeated supramaximal treadmill sprints. The ICV test during treadmill running provides reliable ICV and W' measures, as well as an estimated recovery time via CRI for men and women.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Appl Physiol (1985). 2004 Aug;97(2):612-8 - PubMed
    1. Sports Med. 2005;35(12):1025-44 - PubMed
    1. Sports Med. 2009;39(4):257-78 - PubMed
    1. J Sports Med Phys Fitness. 2011 Mar;51(1):18-25 - PubMed
    1. Eur J Appl Physiol. 2010 Oct;110(3):627-34 - PubMed