Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2011 Aug;19(4):267-74.
doi: 10.3109/09273948.2011.583376.

Morphologic assessment for glaucoma in the Multicenter Uveitis Steroid Treatment (MUST) trial

Collaborators, Affiliations
Randomized Controlled Trial

Morphologic assessment for glaucoma in the Multicenter Uveitis Steroid Treatment (MUST) trial

Sapna S Gangaputra et al. Ocul Immunol Inflamm. 2011 Aug.

Abstract

Purpose: To compare Reading Center (RC) cup-to-disc ratio (CDR) assessment from stereoscopic photographs with clinician estimation in a uveitis clinical trial.

Methods: Clinical estimation of CDR was performed by ophthalmologists via dilated biomicroscopy. Photographic evaluation was performed at an independent RC by masked, certified evaluators. Quality control was performed by repeat grading of 77 randomly selected images.

Results: Among 479 eyes with uveitis, 353 eyes had clinical and photographic grades for CDR. Agreement between clinical and RC grading was fair, with exact agreement of 29%. Agreement within 0.1 and 0.2 CDR was 70 and 93%, respectively (weighted κ = .34). Intergrader reproducibility at the RC was better (weighted κ = .59, ICC 0.74).

Conclusion: Morphologic assessment of cup to disc ratio is an important outcome and safety measure for determining glaucomatous damage in clinical trials. Masked RC measurements are more likely to be accurate than biomicroscopic grading in identifying meaningful anatomical change associated with glaucoma.

PubMed Disclaimer

Conflict of interest statement

Declaration of interest: The authors report no conflicts of interest. The authors alone are responsible for the content and writing of the paper

Figures

Figure 1
Figure 1
Comparison of cup-disc ratios between reading center grades and clinician
Figure 2
Figure 2
Reproducibility of cup-disc ratio grades at the reading center.

References

    1. Kempen JH, Altaweel MM, Holbrook JT, Jabs DA, Sugar EA Multicenter Uveitis Steroid Treatment Trial Research Group. The multicenter uveitis steroid treatment trial: rationale, design, and baseline characteristics. Am J Ophthalmol. 2010 Apr;149(4):550–561. - PMC - PubMed
    1. Sallam A, Sheth HG, Habot-Wilner Z, Lightman S. Outcome of raised intraocular pressure in uveitic eyes with and without a corticosteroid-induced hypertensive response. Am J Ophthalmol. 2009 Aug;148(2):207–213. - PubMed
    1. Nazm N, Dubey S, Gandhi M, Pegu J. Re: Outcome of raised intraocular pressure in uveitic eyes with and without a corticosteroid-induced hypertensive response. Am J Ophthalmol. 2010 Mar;149(3):525–6. author reply 526–7. - PubMed
    1. Callanan DG, Jaffe GJ, Martin DF, Pearson PA, Comstock TL. Treatment of posterior uveitis with a fluocinolone acetonide implant: three-year clinical trial results. Arch Ophthalmol. 2008 Sep;126(9):1191–201. - PubMed
    1. Jaffe GJ, Martin D, Callanan D, Pearson PA, Levy B, Comstock T Fluocinolone Acetonide Uveitis Study Group. Fluocinolone acetonide implant (Retisert) for noninfectious posterior uveitis: thirty-four-week results of a multicenter randomized clinical study. Ophthalmology. 2006 Jun;113(6):1020–7. - PubMed

Publication types