Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2012 Apr;83(4):491-7.
doi: 10.1902/jop.2011.110320. Epub 2011 Jul 22.

Bacterial leakage in implants with different implant-abutment connections: an in vitro study

Comparative Study

Bacterial leakage in implants with different implant-abutment connections: an in vitro study

Bartolomeo Assenza et al. J Periodontol. 2012 Apr.

Abstract

Background: Two-piece implants present gaps and cavities between the implant and the abutment, and these hollow spaces can act as a trap for bacteria. The aim of the present in vitro study was to evaluate the migration of two different microbial species from the inside to the outside of the implant-abutment assembly in three different connection types.

Methods: A total of 30 implants (10 implants per group) were used. The implants presented a screwed trilobed connection (group 1), a cemented connection (group 2), and an internal conical connection (group 3). The inner parts of five implants, per group, were inoculated with Pseudomonas aeruginosa suspension and the remaining five implants, per group, with Aggregatibacter actinomycetemcomitans. The penetration of bacteria into the surrounding solution was determined by the observation of turbidity of the broth.

Results: In group 1, bacterial contamination was found in six of 10 implants. In group 2, no contaminated samples were found. In group 3, bacterial contamination was found in one implant of 10. Statistically significant differences were detected between group 1 versus group 3 (P <0.05) and between group 1 versus group 2 (P <0.01), whereas no significant differences were found when comparing group 2 versus group 3 (P >0.05).

Conclusion: The present study confirms previous results about the hermeticity of the cement-retained implant-abutment assembly, the very low permeability to bacteria of the conical implant-abutment connection, and the high prevalence of bacterial penetration of screw-retained implant-abutment assemblies.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

Substances

LinkOut - more resources