Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2012 May;21(5):612-7.
doi: 10.1016/j.jse.2011.04.005. Epub 2011 Jul 23.

A three-dimensional analysis of humeral head retroversion

Affiliations
Comparative Study

A three-dimensional analysis of humeral head retroversion

Fraser Harrold et al. J Shoulder Elbow Surg. 2012 May.

Abstract

Introduction: The anatomic neck of the humerus is used as a reference for the osteotomy in shoulder arthroplasty. Resection along the anterior portion of the cartilage/metaphyseal border is assumed to remove a cap of a sphere that can accurately be replaced with a spherical prosthetic implant oriented precisely to the original articular surface. The aim of this study was to determine the variability in retroversion of the cartilage/metaphyseal interface in the axial plane.

Methods: Surface topography data for 24 arms from deceased donors were collected by using a hand-held digitizer and a surface laser scanner. Data were combined into the same coordinate system and graphically presented. The humeral head was divided into 6 sections in the axial plane and the retroversion angle measured at each level with reference to the transepicondylar axis at the elbow.

Results: The mean retroversion of the humeral head at the midpoint between the superior and inferior margins was 18.6°. The angle increased as the position of the measurement moved superiorly to 22.5°. In contrast, the retroversion angle reduced as the position of measurement moved more inferiorly to 14.3°.

Discussion: The results suggest that the cartilage/metaphyseal interface is not circular encompassing a spherical cap of a sphere. Furthermore, there appears to be a clockwise torsion of the cartilage/metaphyseal interface about the transverse axis from its medial to lateral aspect.

Conclusion: The cartilage/metaphyseal interface shows a degree of variability that makes it an unreliable landmark to perform an osteotomy when the anterior aspect of the interface is used.

PubMed Disclaimer

Publication types

LinkOut - more resources