Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2011 Aug;72(8):1029-37.
doi: 10.2460/ajvr.72.8.1029.

Comparison of flow-mediated vasodilation in femoral and brachial arteries in healthy dogs

Affiliations
Free article
Comparative Study

Comparison of flow-mediated vasodilation in femoral and brachial arteries in healthy dogs

Ian D Jones et al. Am J Vet Res. 2011 Aug.
Free article

Abstract

Objective: To compare flow-mediated vasodilation (FMD) measurements in brachial and femoral arteries of healthy dogs habituated to the assessment method, evaluate repeatability of these measurements, and investigate effects of blood pressure cuff inflation time on femoral artery FMD measurements.

Animals: 11 healthy adult Miniature Schnauzers.

Procedures: Arterial luminal diameter and blood flow velocity integral (FVI) were measured before and after cuff inflation of 5 minutes' (brachial and femoral arteries) or 3 minutes' duration (femoral artery) in separate experiments. A blood pressure cuff was inflated to > 200 mm Hg distal to each imaging site to increase local blood flow to induce reactive hyperemia. Changes in FVI after cuff deflation, FMD, and between-dog and within-dog coefficients of variation (CVs) were determined.

Results: After cuff inflation of 5 minutes' duration, greater changes were detected in median change in FVI and FMD of brachial arteries (174.0% and 8.0%, respectively), compared with values determined for femoral arteries (32.0% and 2.1%, respectively). Between-dog CV for brachial artery FMD was 34.0%, compared with 89.6% for femoral arteries, and within-dog CV was 32.5% for brachial arteries versus 51.6% for femoral arteries after cuff inflation of 5 minutes' duration.

Conclusions and clinical relevance: In healthy Miniature Schnauzers, FMD was greater and more repeatable in brachial arteries than in femoral arteries. Reactive hyperemia was inconsistently induced in femoral arteries following 3- or 5-minute cuff inflation times. Brachial, but not femoral, artery FMD measurement is a potentially useful research technique for measurement of endothelial function in dogs.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources