Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011;22(7):485-94.
doi: 10.3109/09537104.2011.592958. Epub 2011 Aug 2.

Optical multichannel (optimul) platelet aggregometry in 96-well plates as an additional method of platelet reactivity testing

Affiliations

Optical multichannel (optimul) platelet aggregometry in 96-well plates as an additional method of platelet reactivity testing

Melissa V Chan et al. Platelets. 2011.

Abstract

Platelet reactivity testing is important for the diagnosis of bleeding disorders, and increasingly to optimise anti-platelet therapy. Traditional light transmission aggregometry is considered the gold standard, whilst 96-well plate aggregometry, founded on similar principles, provides a higher throughput screening method. Despite the widespread use of both, methodologies and outputs vary widely between laboratories. We report a methodological approach towards providing a standardised optical detection of platelet aggregation (optimul method) based upon 96-well plate aggregometry. Individual wells of half-area 96-well plates were coated with gelatine and one of seven concentrations of arachidonic acid (AA), adenosine diphosphate (ADP), collagen, epinephrine (EPI), ristocetin, TRAP-6 amide or U46619, before being lyophilised, vacuum-sealed, foil-packed and stored at room temperature for up to 24 weeks. For platelet testing, 40 µl of platelet-rich plasma was added to each well. Platelet aggregation was determined by changes in light absorbance, release of ATP/ADP by luminescence and release of thromboxane (TX) A(2) by ELISA. Some experiments were conducted in the presence of aspirin (30 µM) or prasugrel active metabolite (PAM; 3 µM). Optimul plates stored for up to 12 weeks permitted reliable detection of concentration-dependent platelet aggregation, ATP/ADP release and TXA₂ production. PAM caused reductions in platelet responses to AA, ADP, collagen, EPI, TRAP-6 and U46619, whilst aspirin inhibited responses to AA, collagen and EPI. We conclude that the optimul method offers a viable, standardised approach, allowing platelet reactivity testing and could provide a broad platelet function analysis without the need for dedicated equipment.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources