Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Oct 10;1(2):e18.
doi: 10.4081/or.2009.e18.

External fixation of "intertrochanteric" fractures

Affiliations

External fixation of "intertrochanteric" fractures

Naseem Ul Gani et al. Orthop Rev (Pavia). .

Abstract

In developing countries, due to limited availability of modern anesthesia and overcrowding of the hospitals with patients who need surgery, high-risk patients with "intertrochanteric" fractures remain unsuita ble for open reduction and internal fixation.The aim of this study was to analyze the results of external fixation of "intertrochanteric" fractures in high-risk geriatric patients in a developing country.The results of 62 ambulatory high-risk geriatric patients with a mean age of 70 years (range 58-90 years) with "intertrochanteric" fractures, in whom external fixation was performed, are reported.Eight patients died during follow-up due to medical causes unrelated to the surgical procedure. So only 54 patients were available for final assessment. Procedure is simple, performed under local anesthesia, requires less time for surgery and is associated with less blood loss. Good fixation and early ambulation was achieved in most of the patients. Average time to union was 14 weeks. Thirty-one patients developed superficial pin tract infection and 28 patients had average shortening of 15 mm due to impaction and varus angulation. Functional outcome was assessed using Judet's point system. Good to excellent results were achieved in 44 patients.This study demonstrated that external fixation of "intertrochantric" fractures performed under local anesthesia offers significant advantage in ambulatory high-risk geriatric patients especially in a developing country.

PubMed Disclaimer

Conflict of interest statement

Conflict of interest: the authors reported no potential conflicts of interests.

Figures

Figure 1
Figure 1
Pre operative radoigraph.
Figure 2
Figure 2
Immediate post operative radiograph.
Figure 3
Figure 3
Radiograph at 14 weeks.
Figure 4
Figure 4
Radiograph after removal of the fixator.

Similar articles

Cited by

References

    1. Zetterberg C, Anderson BJ. Fractures of the proximal end of the femur in Goteborg, Sweden. Acta Orthop Scand. 1982;53:419–26. - PubMed
    1. Aufrane OE, Jones WN, Truner RH. Severely communited intertrochanteric hip fractures. JAMA. 1967;199:140–3. - PubMed
    1. Gotfreed Y. Intertrochanteric fractures in high risk geriatric patients treated by external fixation. Clin Orthop. 1985;6:769–74. - PubMed
    1. Dhal A, Varghese M, Bhasin VB. External fixation of intertrochanteric fractures in high risk geriatric fractures of the femur. J Bone Joint Surg. 1991;73-B:955–8. - PubMed
    1. Stinchfield FE, Cooperman B, Shea CE. Replacement of the femoral head by Judet or Austin Moore prosthesis. J Bone Joint Surg. 1957;39A:1043–58. - PubMed

LinkOut - more resources