Radioguided occult lesion localization versus wire-guided localization for non-palpable breast lesions: randomized controlled trial
- PMID: 21808866
- PMCID: PMC3129952
- DOI: 10.1590/s1807-59322011000600014
Radioguided occult lesion localization versus wire-guided localization for non-palpable breast lesions: randomized controlled trial
Abstract
Aim: This prospective randomized clinical study was conducted to compare radioguided occult lesion localization (ROLL) with wire-guided localization to evaluate optimum localization techniques for non-palpable breast lesions.
Methods: A total of 108 patients who were undergoing an excisional biopsy for non-palpable breast lesions requiring pathologic diagnosis were randomly assigned to the ROLL group (n = 56) and wire-guided localization group (n = 52). In the study, patients' characteristics, radiological abnormalities, radiological technique of localization, localization time, operation time, weight of the excised specimen, clearance margins, pathological diagnosis and perioperative complications were assessed.
Results: There were no differences between the two groups in terms of age, radiological abnormalities and localization technique (p = non-significant for all). ROLL techniques resulted in 100% retrieval of the lesions; for the wire-guided localization technique, 98%. Both localization time and operation time were significantly reduced with the ROLL technique (p = significant for all). The weight of the specimen was significantly lower in the ROLL group than in the wire-guided localization group (p = significant). The overall complication rate and pathological diagnosis were similar for both groups (p = non-significant for all). Clear margins were achieved in 91% of ROLL patients and in 53% of wire-guided localization patients, and the difference was significant.
Conclusions: The present study indicated that the ROLL technique is as effective as wire-guided localization for the excision of non-palpable breast lesions. In addition, ROLL improved the outcomes by reducing localization and operation time, preventing healthy tissue excision and achieving clearer margins.
References
-
- Cady B, Stone MD, Schuler JG, Thakur R, Wanner MA, Lavin PT. The new era in breast cancer. Invasion, size and nodal involvement dramatically decreasing as a result of mammographic screening. Arch Surg. 1996;131:301–8. - PubMed
-
- McLelland R. Screening mammography. Cancer. 1991;67:1129–31. 10.1002/1097-0142(19910215)67:4+<1129::AID-CNCR2820671505>3.0.CO;2-3 - DOI - PubMed
-
- Goedde TA, Frykberg ER, Crump JM, Lay SF, Turetsky DB, Linden SS. The impact of mammography on breast biopsy. Am Surg. 1992;58:661–6. - PubMed
-
- Franceschi D, Crowe J, Zollinger R, Duchesneau R, Shenk R, Stefanek G, et al. Breast biopsy for calcifications in nonpalpable breast lesions. A prospective study. Arch Surg. 1990;125:170–3. - PubMed
-
- Papatestas AE, Hermann D, Hermann G, Tsevdos C, Lesnick G. Surgery for nonpalpable breast lesions. Arch Surg. 1990;125:399–402. - PubMed