Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2011 Aug 9;58(7):729-37.
doi: 10.1016/j.jacc.2011.04.024.

Reduction of the risk of recurring heart failure events with cardiac resynchronization therapy: MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy)

Affiliations
Free article
Randomized Controlled Trial

Reduction of the risk of recurring heart failure events with cardiac resynchronization therapy: MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy)

Ilan Goldenberg et al. J Am Coll Cardiol. .
Free article

Abstract

Objectives: The evaluation of the risk of recurring heart failure events (HFEs) was a pre-specified substudy of MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy).

Background: There are limited data regarding the effect of cardiac resynchronization therapy with a defibrillator (CRT-D) on the occurrence of recurring heart failure episodes after a first post-implantation HFE.

Methods: Data with regard to recurring HFEs were prospectively collected for all 1,820 MADIT-CRT participants. The CRT-D versus defibrillator-only risk for nonfatal first- and subsequent-HFEs was assessed by Cox proportional hazards and Andersen-Gill proportional intensity regression modeling, respectively, in efficacy analyses recognizing active device-type during follow-up.

Results: Multivariate analysis showed that CRT-D was associated with a significant reduction in the risk of a first HFE (hazard ratio [HR]: 0.54, 95% confidence interval [CI]: 0.44 to 0.67, p < 0.001) and with a similar magnitude of reduction in the risk of HFEs subsequent to a first post-enrollment event (HR: 0.62, 95% CI: 0.45 to 0.85, p = 0.003). The benefit of CRT-D for the prevention of first and subsequent HFEs was pronounced among patients with left bundle branch block (HR: 0.38, 95% CI: 0.29 to 0.49, p < 0.001; and HR: 0.50, 95% CI: 0.33 to 0.76, p = 0.001, respectively) and nonsignificant in non-left bundle branch block patients (HR: 1.12, 95% CI: 0.77 to 1.64, p = 0.55; and HR: 0.99, 95% CI: 0.58 to 1.69, p = 0.96, respectively; p values for interaction: p < 0.001 and p = 0.06, respectively). The occurrences of first and second HFEs were associated with 7- and nearly 19-fold respective increases in the risk of subsequent mortality.

Conclusions: In the MADIT-CRT trial, the benefit of cardiac resynchronization therapy for the reduction in recurring HFEs was maintained after the occurrence of a first post-enrollment event. The occurrence of HFEs greatly increased the risk of death. (Multicenter Automatic Defibrillator Implantation With Cardiac Resynchronization Therapy; NCT00180271).

PubMed Disclaimer

Comment in

Publication types

Associated data