Fast high-resolution brain imaging with balanced SSFP: Interpretation of quantitative magnetization transfer towards simple MTR
- PMID: 21820061
- DOI: 10.1016/j.neuroimage.2011.07.038
Fast high-resolution brain imaging with balanced SSFP: Interpretation of quantitative magnetization transfer towards simple MTR
Abstract
Magnetization transfer (MT) reflects the exchange of magnetization between protons bound to macromolecules, such as lipids and proteins, and protons in free liquid, and thus might be an early marker for subtle and undetermined pathologic changes in tissue. Detailed analysis of the entire MT phenomenon, however, commonly requires extensive data acquisition and scanning time, and hence is only of limited clinical interest. Therefore, in practice, magnetization transfer effects are commonly confined into a simple ratio measure, the so-called magnetization transfer ratio (MTR), calculated from a MT-weighted and a non-MT-weighted image. However, subtle physiologic and pathologic changes in tissue, invaluable for specific diagnostic imaging, may be lost since MTR-values depend not only on quantitative magnetization transfer (qMT) parameters but also on sequence parameters and relaxation properties. In order to evaluate and assess the diagnostic specificity of MTR versus qMT, high-resolution whole brain MT data was collected from twelve healthy volunteers using balanced steady-state free precession (bSSFP). In contrast to common MT imaging based on spoiled gradient echo (SPGR) sequences, whole brain qMT imaging can be performed with MT-sensitized bSSFP within a clinically feasible acquisition time. Hence, MT-sensitized bSSFP provides access to both MTR and qMT parameters within a clinical setting. The reliability and possible diagnostic value of MTR are analyzed for twelve white matter (WM) and eleven gray matter (GM) structures of the normal appearing brain. Strong correlations were found within and between longitudinal and transverse relaxation times (T1, T2) and MT parameters (ratio between macromolecular and water protons, F, and magnetization exchange rate, kf), whereas weaker correlations were observed between MTR-values and relaxation times or MT parameters. Structures with highly similar MTR-values, such as the crus cerebri and the anterior commissure in the WM, or the pallidum and the amygdala in the GM, however, were also found that showed significant differences in most quantitative parameters. This observation was confirmed from simulations revealing that the overall effect on MTR from an increase (decrease) in relaxation times may be counterbalanced with a decrease (increase) in MT parameters. These findings corroborate the expectation that qMT is superior to MTR imaging, especially for the evaluation and assessment of pathologic or physiological changes in healthy and pathologic brain tissue.
Copyright © 2011 Elsevier Inc. All rights reserved.
Similar articles
-
Characterization of normal appearing brain structures using high-resolution quantitative magnetization transfer steady-state free precession imaging.Neuroimage. 2010 Aug 15;52(2):532-7. doi: 10.1016/j.neuroimage.2010.04.242. Epub 2010 Apr 27. Neuroimage. 2010. PMID: 20430101
-
Comparison between balanced steady-state free precession and standard spoiled gradient echo magnetization transfer ratio imaging in multiple sclerosis: methodical and clinical considerations.Neuroimage. 2015 Mar;108:87-94. doi: 10.1016/j.neuroimage.2014.12.045. Epub 2014 Dec 20. Neuroimage. 2015. PMID: 25536494
-
Imaging of Primary Brain Tumors and Metastases with Fast Quantitative 3-Dimensional Magnetization Transfer.J Neuroimaging. 2015 Nov-Dec;25(6):1007-14. doi: 10.1111/jon.12222. Epub 2015 Feb 20. J Neuroimaging. 2015. PMID: 25702714
-
Magnetization transfer magnetic resonance imaging: a clinical review.Top Magn Reson Imaging. 1996 Aug;8(4):214-30. Top Magn Reson Imaging. 1996. PMID: 8870180 Review.
-
Magnetization transfer imaging of the spinal cord and the optic nerve in patients with multiple sclerosis.Neurology. 1999;53(5 Suppl 3):S46-8. Neurology. 1999. PMID: 10496211 Review.
Cited by
-
Longitudinal analysis of new multiple sclerosis lesions with magnetization transfer and diffusion tensor imaging.Eur Radiol. 2024 Mar;34(3):1680-1691. doi: 10.1007/s00330-023-10173-6. Epub 2023 Sep 2. Eur Radiol. 2024. PMID: 37658894 Free PMC article.
-
Nonconventional MRI and microstructural cerebral changes in multiple sclerosis.Nat Rev Neurol. 2015 Dec;11(12):676-86. doi: 10.1038/nrneurol.2015.194. Epub 2015 Nov 3. Nat Rev Neurol. 2015. PMID: 26526531 Review.
-
Quantitative MR imaging of two-pool magnetization transfer model parameters in myelin mutant shaking pup.Neuroimage. 2012 Sep;62(3):1390-8. doi: 10.1016/j.neuroimage.2012.05.077. Epub 2012 Jun 1. Neuroimage. 2012. PMID: 22664569 Free PMC article.
-
Quantitative magnetization transfer MRI of desmoplasia in pancreatic ductal adenocarcinoma xenografts.NMR Biomed. 2013 Dec;26(12):1688-95. doi: 10.1002/nbm.3004. Epub 2013 Aug 12. NMR Biomed. 2013. PMID: 23940016 Free PMC article.
-
Unbiased signal equation for quantitative magnetization transfer mapping in balanced steady-state free precession MRI.Magn Reson Med. 2022 Jan;87(1):446-456. doi: 10.1002/mrm.28940. Epub 2021 Jul 31. Magn Reson Med. 2022. PMID: 34331470 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources