The use of drug-eluting stents in the management of transplant renal artery stenosis
- PMID: 21827621
- DOI: 10.1111/j.1600-6143.2011.03652.x
The use of drug-eluting stents in the management of transplant renal artery stenosis
Abstract
Transplant renal artery stenosis (TRAS) is a common occurrence following kidney transplantation with an incidence rate ranging from 6% to 23%. A single-center retrospective study was conducted to examine the use of drug-eluting stents (DES) in eligible patients with hemodynamically significant TRAS. Between March 2008 and January 2011, 12 patients were diagnosed with TRAS with reference vessel diameter measuring <5 mm and underwent endovascular intervention (EVI) with DES placement. TRAS was detected within the first year posttransplantation in a majority of these patients (83%) and manifested as hypertension (100%), allograft dysfunction (100%) and edema (58%). Procedural success rate was 100%. Patients were followed for a mean period of 16 ± 10 months. Blood pressure improved from a mean of 156/82 to 138/73 mmHg at the end of the follow-up period. In 11/12 patients, serum creatinine improved from 3.1 ± 1.3 mg/dL to 2.3 ± 0.5 mg/dL at the end of the follow-up period. TRAS of early onset is readily amenable to EVI with stent placement resulting in improvement in blood pressure control and allograft function.