LC-MS/MS method for the quantification of myo- and chiro-inositol as the urinary biomarkers of insulin resistance in human urine
- PMID: 21830227
- DOI: 10.1002/bmc.1682
LC-MS/MS method for the quantification of myo- and chiro-inositol as the urinary biomarkers of insulin resistance in human urine
Abstract
A simple LC-MS/MS method has been developed and validated for the quantification of endogenous myo- and chiro-inositol in human urine. myo- and chiro-Inositol were completely resolved from other carbohydrates and there were no interference peaks in human urine. The correlation coefficient (n = 3) was greater than 0.9991 over the range 0.05-25.0 µg/mL with the weighted (1/C²) least square method. Precision (%RSD) and accuracy (%RE) were 0-10.0% and 0-6.0% for the intra-day assay (n = 5) and 0-14.3% and 0-10.0% for the inter-day assay (n = 5). myo- and chiro-Inositol have been shown to be stable in human urine stored at room temperature and for three freeze-thaw cycles.
Copyright © 2011 John Wiley & Sons, Ltd.
Similar articles
-
Development and validation of an LC/MS/MS procedure for the quantification of endogenous myo-inositol concentrations in rat brain tissue homogenates.Anal Chem. 2004 Aug 15;76(16):4901-8. doi: 10.1021/ac049746w. Anal Chem. 2004. PMID: 15307804
-
Relationships of plasma C-peptide and gender to the urinary excretion of inositols in older people.Horm Metab Res. 2001 Jan;33(1):44-51. doi: 10.1055/s-2001-12626. Horm Metab Res. 2001. PMID: 11280715
-
LC-MS/MS determination of helicid in human plasma and its application in pharmacokinetic studies.J Chromatogr B Analyt Technol Biomed Life Sci. 2011 Nov 15;879(30):3607-11. doi: 10.1016/j.jchromb.2011.10.001. Epub 2011 Oct 7. J Chromatogr B Analyt Technol Biomed Life Sci. 2011. PMID: 22024391
-
Quantitative determination of BAF312, a S1P-R modulator, in human urine by LC-MS/MS: prevention and recovery of lost analyte due to container surface adsorption.J Chromatogr B Analyt Technol Biomed Life Sci. 2010 Feb 15;878(5-6):583-9. doi: 10.1016/j.jchromb.2009.12.031. Epub 2010 Jan 4. J Chromatogr B Analyt Technol Biomed Life Sci. 2010. PMID: 20097141
-
Quantitative determination of 8-isoprostaglandin F(2α) in human urine using microfluidic chip-based nano-liquid chromatography with on-chip sample enrichment and tandem mass spectrometry.J Chromatogr A. 2011 Apr 15;1218(15):2085-90. doi: 10.1016/j.chroma.2010.10.091. Epub 2010 Oct 30. J Chromatogr A. 2011. PMID: 21081240
Cited by
-
Quantification of myo-inositol, 1,5-anhydro- D-sorbitol, and D-chiro-inositol using high-performance liquid chromatography with electrochemical detection in very small volume clinical samples.Biomed Chromatogr. 2015 Nov;29(11):1629-36. doi: 10.1002/bmc.3470. Epub 2015 May 26. Biomed Chromatogr. 2015. PMID: 26010453 Free PMC article.
-
Development Rapid Analytical Methods for Inositol as a Trace Component by HPLC and LC-MS/MS in Infant Formula.Korean J Food Sci Anim Resour. 2015;35(4):466-72. doi: 10.5851/kosfa.2015.35.4.466. Epub 2015 Aug 31. Korean J Food Sci Anim Resour. 2015. PMID: 26761867 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous