High-resolution retinal imaging with micro adaptive optics system
Abstract
Based on the dynamic characteristics of human eye aberration, a microadaptive optics retina imaging system set is established for real-time wavefront measurement and correction. This paper analyzes the working principles of a 127-unit Hartmann-Shack wavefront sensor and a 37-channel micromachine membrane deformable mirror adopted in the system. The proposed system achieves wavefront reconstruction through the adaptive centroid detection method and the mode reconstruction algorithm of Zernike polynomials, so that human eye aberration can be measured accurately. Meanwhile, according to the adaptive optics aberration correction control model, a closed-loop iterative aberration correction algorithm based on Smith control is presented to realize efficient and real-time correction of human eye aberration with different characteristics, and characteristics of the time domain of the system are also optimized. According to the experiment results tested on a USAF 1951 standard resolution target and a living human retina (subject ZHY), the resolution of the system can reach 3.6 LP/mm, and the human eye wavefront aberration of 0.728λ (λ=785 nm) can be corrected to 0.081λ in root mean square (RMS) so as to achieve the diffraction limit (Strehl ratio is 0.866), then high-resolution retina images are obtained.
Similar articles
-
Wavefront-coding technique for inexpensive and robust retinal imaging.Opt Lett. 2014 Jul 1;39(13):3986-8. doi: 10.1364/OL.39.003986. Opt Lett. 2014. PMID: 24978788
-
Dual wavefront sensing channel monocular adaptive optics system for accommodation studies.Opt Express. 2009 Sep 28;17(20):18229-40. doi: 10.1364/OE.17.018229. Opt Express. 2009. PMID: 19907614
-
Effects of monochromatic aberration on visual acuity using adaptive optics.Optom Vis Sci. 2009 Jul;86(7):868-74. doi: 10.1097/OPX.0b013e3181adfdff. Optom Vis Sci. 2009. PMID: 19521271
-
Wave aberration of human eyes and new descriptors of image optical quality and visual performance.J Cataract Refract Surg. 2010 Feb;36(2):313-31. doi: 10.1016/j.jcrs.2009.09.026. J Cataract Refract Surg. 2010. PMID: 20152616 Review.
-
[Contemporary applications of wavefront aberrometry in ophthalmology practice].Klin Oczna. 2012;114(1):75-8. Klin Oczna. 2012. PMID: 22783752 Review. Polish.
Cited by
-
Eye-pupil displacement and prediction: effects on residual wavefront in adaptive optics retinal imaging.Biomed Opt Express. 2016 Feb 25;7(3):1051-73. doi: 10.1364/BOE.7.001051. eCollection 2016 Mar 1. Biomed Opt Express. 2016. PMID: 27231607 Free PMC article.
-
Adaptive optics retinal imaging with automatic detection of the pupil and its boundary in real time using Shack-Hartmann images.Appl Opt. 2017 Aug 20;56(24):6748-6754. doi: 10.1364/AO.56.006748. Appl Opt. 2017. PMID: 29048013 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources