Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1990 Mar;33(3):168-73.
doi: 10.1007/BF00404045.

No evidence for isotope discrimination of tritiated glucose tracers in measurements of glucose turnover rates in man

Affiliations

No evidence for isotope discrimination of tritiated glucose tracers in measurements of glucose turnover rates in man

V A Koivisto et al. Diabetologia. 1990 Mar.

Abstract

Under non-steady-state conditions, glucose turnover rates determined with tritiated glucose tracers are often underestimated. To examine whether isotope discrimination or a tracer contaminant can contribute to this, we compared the turnover rates of unlabelled and tritiated glucose under isotopic steady-state conditions. The turnover rates were measured in 20 healthy subjects at two insulin concentrations (79 +/- 3 mU.l-1 and 704 +/- 62 mU.l-1). Euglycaemia was maintained by infusing unlabelled glucose mixed with (3(3)H)- or (6(3)H)-glucose. In both studies, the isotopically determined glucose disposal rate was virtually identical to the exogenous glucose infusion rate (low insulin 7.66 +/- 0.48 vs 7.58 +/- 0.44 mg.kg-1.min-1, high insulin 13.36 +/- 0.74 vs 13.55 +/- 0.98 mg.kg-1.min-1). The individual values were correlated in both the low (r = 0.85, p less than 0.001) and high dose insulin (r = 0.81, p less than 0.001) studies. Tritiated glucose specific activities were also compared in arterialized and deep venous blood across forearm tissues during the high-dose insulin infusion. Glucose specific activities were similar in arterialized and deep venous blood when analysed with HPLC and conventional methods. In summary: (1) Under isotopic steady-state conditions the turnover rates of unlabelled and labelled glucoses are similar. (2) Unlabelled and labelled glucose are handled identically across forearm tissues. (3) We found no tracer impurity in our tritiated glucose preparations. We conclude that (3(3)H)- and (6(3)H)-glucose tracers can be used to reliably measure glucose turnover rates in man.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Clin Invest. 1986 Dec;78(6):1479-86 - PubMed
    1. Am J Physiol. 1975 Dec;229(6):1662-7 - PubMed
    1. J Appl Physiol. 1976 Oct;41(4):565-73 - PubMed
    1. Diabetes. 1988 Aug;37(8):1025-34 - PubMed
    1. Endocr Rev. 1985 Winter;6(1):45-86 - PubMed

Publication types