Clinical evaluation of stethoscope-guided inflation of tracheal tube cuffs
Abstract
Tracheal tube cuffs are commonly inflated to pressures exceeding the recommended upper limit of 30 cmH(2)O. We evaluated whether a stethoscope-guided method of cuff inflation results in pressures within the recommended range. Patients were randomly assigned to receive one of two methods of cuff inflation. In the standard 'just seal' group, air was introduced into the tracheal cuff until the audible leak at the mouth disappeared. In the stethoscope-guided group, air was introduced into the cuff until a change from harsh to soft breath sounds occurred, whilst listening with a stethoscope bell placed over the thyroid cartilage. Twenty-five patients were recruited to each group. The median (IQR [range]) cuff pressure in the 'just seal' group was 34 (28-40 [18-49]) cmH(2)O, and in the stethoscope-guided group was 20 (20-26 [16-28]) cmH(2)O, p < 0.0001. The stethoscope-guided method of tracheal tube cuff inflation is a novel, simple technique that reliably results in acceptable tracheal cuff pressures.
© 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.
Similar articles
-
A visual stethoscope to detect the position of the tracheal tube.Anesth Analg. 2009 Dec;109(6):1836-42. doi: 10.1213/ANE.0b013e3181bb4967. Anesth Analg. 2009. PMID: 19923511
-
Endotracheal Tube Cuff Inflation Methods in School-Age Children: Flow-Volume Loop-Guided Versus Stethoscope-Guided.Respir Care. 2025 Feb;70(2):176-183. doi: 10.1089/respcare.12076. Respir Care. 2025. PMID: 39964846 Clinical Trial.
-
The effect of pilot balloon design on estimation of safe tracheal tube cuff pressure.Anaesthesia. 2010 Aug;65(8):785-91. doi: 10.1111/j.1365-2044.2010.06413.x. Epub 2010 Jun 22. Anaesthesia. 2010. PMID: 20573148
-
Do current methods for endotracheal tube cuff inflation create pressures above the recommended range? A review of the evidence.J Perioper Pract. 2013 Dec;23(12):292-5. doi: 10.1177/175045891302301205. J Perioper Pract. 2013. PMID: 24404708 Review.
-
'The old guessing tube': 200 years of the stethoscope.QJM. 2017 Jan;110(1):9-10. doi: 10.1093/qjmed/hcw108. Epub 2016 Aug 2. QJM. 2017. PMID: 27486261 Review. No abstract available.
Cited by
-
The Relationship between Cuff Pressure and Air Injection Volume of Endotracheal Tube: A Study with Sheep Trachea Ex Vivo.Appl Bionics Biomech. 2022 Jun 29;2022:1748233. doi: 10.1155/2022/1748233. eCollection 2022. Appl Bionics Biomech. 2022. Retraction in: Appl Bionics Biomech. 2023 Nov 29;2023:9812179. doi: 10.1155/2023/9812179. PMID: 36324632 Free PMC article. Retracted.
-
Comparison of endotracheal tube cuff pressure values before and after training seminar.J Clin Monit Comput. 2018 Jun;32(3):527-531. doi: 10.1007/s10877-017-0046-7. Epub 2017 Jul 22. J Clin Monit Comput. 2018. PMID: 28733939
-
Comparison between Two Endotracheal Tube Cuff Inflation Methods; Just-Seal Vs. Stethoscope-Guided.J Clin Diagn Res. 2017 Jun;11(6):UC01-UC03. doi: 10.7860/JCDR/2017/26301.10017. Epub 2017 Jun 1. J Clin Diagn Res. 2017. PMID: 28764268 Free PMC article.
-
Comparative evaluation of three methods of endotracheal tube cuff inflation for adequacy of seal.J Anaesthesiol Clin Pharmacol. 2022 Oct-Dec;38(4):588-593. doi: 10.4103/joacp.JOACP_560_20. Epub 2022 Jun 15. J Anaesthesiol Clin Pharmacol. 2022. PMID: 36778817 Free PMC article.
-
Tracheal tube cuff inflation guided by pressure volume loop closure associated with lower postoperative cuff-related complications: Prospective, randomized clinical trial.Saudi J Anaesth. 2014 Jul;8(3):328-34. doi: 10.4103/1658-354X.136422. Saudi J Anaesth. 2014. PMID: 25191181 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical