Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Aug;4(8):851-8.
doi: 10.1016/j.jcin.2011.03.019.

Transfemoral aortic valve implantation new criteria to predict vascular complications

Affiliations
Free article

Transfemoral aortic valve implantation new criteria to predict vascular complications

Kentaro Hayashida et al. JACC Cardiovasc Interv. 2011 Aug.
Free article

Abstract

Objectives: This study sought to evaluate the incidence, impact, and predictors of vascular complications in transcatheter aortic valve implantation (TAVI).

Background: Vascular complications increase morbidity and mortality in transfemoral TAVI; however, there remains a paucity of data describing these serious events.

Methods: We performed a prospective cohort study of 130 consecutive transfemoral TAVI recipients. Vascular complications were defined by the Valve Academic Research Consortium (VARC) criteria. The ratio of the sheath outer diameter (in millimeters) to the minimal femoral artery diameter (in millimeters) defined the sheath to femoral artery ratio (SFAR).

Results: In our cohort of elderly patients (83.3 ± 5.9 years), the logistic EuroScore was 25.8% ± 11.9%. The Edwards valve was used in 102 cases (18- to 24-F) and the CoreValve in 27 (18-F). The minimal femoral artery diameter was 8.17 ± 1.14 mm, and the calcification (0 to 3) and tortuosity scores (0 to 3) were 0.58 ± 0.72 and 0.28 ± 0.53, respectively. The mean sheath diameter was 8.10 ± 0.82 mm, and the mean SFAR was 0.99 ± 0.16. Vascular complications occurred in 27.6% (VARC major: 17.3%, minor: 10.2%), and major vascular complications predicted 30-day mortality (22.7% vs. 7.6%, p = 0.049). The SFAR (hazard ratio [HR]: 186.20, 95% confidence interval [CI]: 4.41 to 7,855.11), center experience (HR: 3.66, 95% CI: 1.17 to 11.49), and femoral calcification (HR: 3.44, 95% CI: 1.16 to 10.17) predicted major complications by multivariate analysis. An SFAR threshold of 1.05 (area under the curve = 0.727) predicted a higher rate of VARC major complications (30.9% vs. 6.9%, p = 0.001) and 30-day mortality (18.2% vs. 4.2%, p = 0.016).

Conclusions: Vascular complications in transfemoral TAVI are relatively frequent. VARC major vascular complications increase 30-day mortality and are predicted by experience, femoral calcification, and SFAR. Routine application of SFAR will improve patient selection for transfemoral TAVI and may improve outcome.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

LinkOut - more resources