. 2011 Oct;32(9):1652-7.
doi: 10.3174/ajnr.A2596. Epub 2011 Aug 18.

Optimal presentation modes for detecting brain tumor progression

Affiliations
Free PMC article

Optimal presentation modes for detecting brain tumor progression

B J Erickson et al. AJNR Am J Neuroradiol. 2011 Oct.
Free PMC article

Abstract

Background and purpose: A common task in radiology interpretation is visual comparison of images. The purpose of this study was to compare traditional side-by-side and in-place (flicker) image presentation modes with advanced methods for detecting primary brain tumors on MR imaging.

Materials and methods: We identified 66 patients with gliomas and 3 consecutive brain MR imaging examinations (a "triplet"). A display application that presented images in side-by-side mode with or without flicker display as well as display of image subtraction or automated change detection information (also with and without flicker display) was used by 3 board-certified neuroradiologists. They identified regions of brain tumor progression by using this display application. Each case was reviewed using all modes (side-by-side presentation with and without flicker, subtraction with and without flicker, and change detection with and without flicker), with results compared via a panel rating.

Results: Automated change detection with or without flicker (P < .0027) as well as subtraction with or without flicker (P < .0027) were more sensitive to tumor progression than side-by-side presentation in cases where all 3 raters agreed. Change detection afforded the highest interrater agreement, followed by subtraction. Clinically determined time to progression was longer for cases rated as nonprogressing by using subtraction images and change-detection images both with and without flicker display mode compared with side-by-side presentation.

Conclusions: Automated change detection and image subtraction, with and without flicker display mode, are superior to side-by-side image comparison.

PubMed Disclaimer

References

    1. J Digit Imaging. 2007 Dec;20(4):321-8 - PubMed
    1. J Digit Imaging. 2007 Jun;20(2):105-13 - PubMed
    1. J Comput Assist Tomogr. 1995 Sep-Oct;19(5):677-91 - PubMed
    1. Acad Radiol. 2006 Apr;13(4):453-60 - PubMed
    1. Radiology. 1997 Apr;203(1):207-9 - PubMed

Publication types