Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2011;75(11):2628-34.
doi: 10.1253/circj.cj-11-0502. Epub 2011 Aug 27.

Incremental diagnostic value of regional myocardial blood flow quantification over relative perfusion imaging with generator-produced rubidium-82 PET

Affiliations
Free article
Clinical Trial

Incremental diagnostic value of regional myocardial blood flow quantification over relative perfusion imaging with generator-produced rubidium-82 PET

Keiichiro Yoshinaga et al. Circ J. 2011.
Free article

Abstract

Background: Myocardial blood flow (MBF) can be measured with positron emission tomography (PET) and its quantification should provide diagnostic information beyond that obtained through standard visual analysis. However, this possibility has not been fully studied with PET and generator-produced rubidium-82 (⁸²Rb). We evaluated regional MBF in segments with and without ischemia using ⁸²Rb PET in patients with coronary artery disease (CAD).

Methods and results: Rest and stress ⁸²Rb PET and coronary angiography were performed for 12 patients with CAD. Based on angiography and relative ⁸²Rb perfusion images, segments were classified into 4 groups (Group A: myocardial ischemia with >70% diameter stenosis; Group B: no ischemia with stenosis; Group C: no ischemia without stenosis; Group D: ischemia without stenosis). Rest MBF was similar among the 4 groups. Groups A and B showed reduced hyperemic MBF compared with Group C (P < 0.05 vs. Group C) [Group A (n=16) 1.28 ± 0.58 ml·min⁻¹·g⁻¹; Group B (n=11) 1.72 ± 0.64 ml·min⁻¹·g⁻¹; Group C (n=9) 2.60 ± 1.09 ml·min⁻¹·g⁻¹; Group D (n=2) 2.33 ml·min⁻¹·g⁻¹]. Coronary flow reserves were inversely correlated with percent diameter stenosis (r=0.76, P < 0.0001).

Conclusions: Segments with ischemia and coronary stenosis had reduced hyperemic MBF. Segments with coronary stenosis without ischemia also had reduced hyperemic MBF compared with non-stenotic segments. MBF quantification using ⁸²Rb PET may provide additional diagnostic information.

PubMed Disclaimer

Publication types

Substances