Ultrasound of the placenta and umbilical cord: a review
- PMID: 21873856
- DOI: 10.1097/RUQ.0b013e318229ffb5
Ultrasound of the placenta and umbilical cord: a review
Abstract
The placenta and umbilical cord play important roles in the development of the growing fetus. The placenta can be clearly identified by the 14th gestational week and should be evaluated during each obstetric ultrasound examination.This article reviews the formation of the placenta and its expected sonographic appearance throughout gestation along with its normal variants. Expected findings in a singleton pregnancy are primarily addressed. The next portion of the article covers placental abnormalities of clinical consequence, including anomalies of appearance, location, and function.The umbilical cord is also discussed, focusing on the relevance of the location of the umbilical cord's insertion into the placenta.
Similar articles
-
Prenatal diagnosis of placenta and umbilical cord pathologies by three-dimensional ultrasound: pictorial essay.Med Ultrason. 2015 Dec;17(4):545-9. doi: 10.11152/mu.2013.2066.174.pdg. Med Ultrason. 2015. PMID: 26649353 Review.
-
Velamentous cord insertion into the lower third of the uterus is associated with intrapartum fetal heart rate abnormalities.Ultrasound Obstet Gynecol. 2006 Apr;27(4):425-9. doi: 10.1002/uog.2645. Ultrasound Obstet Gynecol. 2006. PMID: 16479618
-
Prenatal detection of velamentous insertion of the umbilical cord: a prospective color Doppler ultrasound study.Ultrasound Obstet Gynecol. 2003 Jun;21(6):564-9. doi: 10.1002/uog.132. Ultrasound Obstet Gynecol. 2003. PMID: 12808673
-
Role of 2-Dimensional Ultrasound Imaging in Placental and Umbilical Cord Morphometry: Literature and Pictorial Review.J Ultrasound Med. 2019 Dec;38(12):3131-3140. doi: 10.1002/jum.15024. Epub 2019 May 29. J Ultrasound Med. 2019. PMID: 31144344 Review.
-
Placental morphologic features and chorionic surface vasculature at term are highly correlated with 3-dimensional sonographic measurements at 11 to 14 weeks.J Ultrasound Med. 2011 Sep;30(9):1171-8. doi: 10.7863/jum.2011.30.9.1171. J Ultrasound Med. 2011. PMID: 21876086
Cited by
-
Discriminative Learning for Automatic Staging of Placental Maturity via Multi-layer Fisher Vector.Sci Rep. 2015 Jul 31;5:12818. doi: 10.1038/srep12818. Sci Rep. 2015. PMID: 26228175 Free PMC article.
-
The structural and functional effects of fine particulate matter from cooking oil fumes on rat umbilical cord blood vessels.Environ Sci Pollut Res Int. 2016 Aug;23(16):16567-78. doi: 10.1007/s11356-016-6821-z. Epub 2016 May 13. Environ Sci Pollut Res Int. 2016. PMID: 27178289
-
Monochorionic diamniotic twins with centrally located and closely spaced umbilical cord insertions in the placenta.Clin Case Rep. 2018 Jan 3;6(2):342-345. doi: 10.1002/ccr3.1332. eCollection 2018 Feb. Clin Case Rep. 2018. PMID: 29445474 Free PMC article.
-
Imaging findings in association with altered maternal alpha-fetoprotein levels during pregnancy.Abdom Radiol (NY). 2020 Oct;45(10):3239-3257. doi: 10.1007/s00261-020-02499-2. Abdom Radiol (NY). 2020. PMID: 32221672 Review.
-
Ultrasonography of Pregnancy in Murciano-Granadina Goat Breed: Fetal Growth Indices and Umbilical Artery Doppler Parameters.Animals (Basel). 2023 Feb 9;13(4):618. doi: 10.3390/ani13040618. Animals (Basel). 2023. PMID: 36830405 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical