Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2011 Jul 1;5(4):952-65.
doi: 10.1177/193229681100500419.

Efficacy of continuous glucose monitoring in improving glycemic control and reducing hypoglycemia: a systematic review and meta-analysis of randomized trials

Affiliations
Meta-Analysis

Efficacy of continuous glucose monitoring in improving glycemic control and reducing hypoglycemia: a systematic review and meta-analysis of randomized trials

Gunjan Y Gandhi et al. J Diabetes Sci Technol. .

Abstract

Objective: We conducted a systematic review and meta-analysis to assess the efficacy of continuous glucose monitoring (CGM) in improving glycemic control and reducing hypoglycemia compared to self-monitored blood glucose (SMBG).

Methods: We searched MEDLINE, EMBASE, Cochrane Central, Web of Science, and Scopus for randomized trials of adults and children with type 1 or type 2 diabetes mellitus (T1DM or T2DM). Pairs of reviewers independently selected studies, assessed methodological quality, and extracted data. Meta-analytic estimates of treatment effects were generated using a random-effects model.

Results: Nineteen trials were eligible and provided data for meta-analysis. Overall, CGM was associated with a significant reduction in mean hemoglobin A1c [HbA1c; weighted mean difference (WMD) of -0.27% (95% confidence interval [CI] -0.44 to -0.10)]. This was true for adults with T1DM as well as T2DM [WMD -0.50% (95% CI -0.69 to -0.30) and -0.70 (95% CI, -1.14 to -0.27), respectively]. No significant effect was noted in children and adolescents. There was no significant difference in HbA1c reduction between studies of real-time versus non-realtime devices (WMD -0.22%, 95% CI, -0.59 to 0.15 versus -0.30%, 95% CI, -0.49 to -0.10; p for interaction 0.71). The quality of evidence was moderate due to imprecision, suggesting increased risk for bias. Data for the incidence of severe or nocturnal hypoglycemia were sparse and imprecise. In studies that reported patient satisfaction, users felt confident about the device and gave positive reviews.

Conclusion: Continuous glucose monitoring seems to help improve glycemic control in adults with T1DM and T2DM. The effect on hypoglycemia incidence is imprecise and unclear. Larger trials with longer follow-up are needed to assess the efficacy of CGM in reducing patient-important complications without significantly increasing the burden of care for patients with diabetes.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Random effect meta-analysis of WMD of HbA1c. Upper and lower limits are limits of 95% CI. JDRF-CGMSG, Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group.
Figure 2
Figure 2
Incidence of hyperglycemia and hypoglycemia. JDRF-CGMSG, Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group.
Figure 3
Figure 3
Rate ratios of hyperglycemia and hypoglycemia. JDRF-CGMSG, Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group.

References

    1. Centers for Disease Control and Prevention. National diabetes fact sheet 2011. http://www.cdc.gov/diabetes/pubs/factsheet11.htm. Accessed April 14, 2011.
    1. DeWitt DE, Hirsch IB. Outpatient insulin therapy in type 1 and type 2 diabetes mellitus: scientific review. JAMA. 2003;289(17):2254–2264. - PubMed
    1. Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group. Tamborlane WV, Beck RW, Bode BW, Buckingham B, Chase HP, Clemons R, Fiallo-Scharer R, Fox LA, Gilliam LK, Hirsch IB, Huang ES, Kollman C, Kowalski AJ, Laffel L, Lawrence JM, Lee J, Mauras N, O'Grady M, Ruedy KJ, Tansey M, Tsalikian E, Weinzimer S, Wilson DM, Wolpert H, Wysocki T, Xing D. Continuous glucose monitoring and intensive treatment of type 1 diabetes. N Engl J Med. 2008;359(14):1464–1476. - PubMed
    1. Golicki DT, Golicka D, Groele L, Pankowska E. Continuous Glucose Monitoring System in children with type 1 diabetes mellitus: a systematic review and meta-analysis. Diabetologia. 2008;51(2):233–240. - PubMed
    1. Chetty VT, Almulla A, Odueyungbo A, Thabane L. The effect of continuous subcutaneous glucose monitoring (CGMS) versus intermittent whole blood finger-stick glucose monitoring (SBGM) on hemoglobin A1c (HBA1c) levels in Type I diabetic patients: a systematic review. Diabetes Res Clin Pract. 2008;81(1):79–87. - PubMed

MeSH terms