Reproducibility of retinal circulation measurements obtained using laser speckle flowgraphy-NAVI in patients with glaucoma
- PMID: 21887100
- PMCID: PMC3162298
- DOI: 10.2147/OPTH.S22093
Reproducibility of retinal circulation measurements obtained using laser speckle flowgraphy-NAVI in patients with glaucoma
Abstract
Background: Laser speckle flowgraphy (LSFG) enables noninvasive quantification of the retinal circulation in glaucoma patients. In this study, we tested the intrasession reproducibility of LSFG-NAVI, a modified LSFG technique.
Methods: Sixty-five eyes from 33 subjects (male (M):female (F) = 17:16) with a mean age of 49.4 ± 11.2 years were examined in this study. Two parameters indicating reproducibility - the coefficient of variation (COV) and the intraclass correlation coefficient (ICC) - were analyzed three times on the same day that mean blur rate (MBR) was measured using LSFG-NAVI. The sites analyzed were the retinal artery and vein, the optic disk, and the choroid. Following classification according to the Glaucoma Hemifield Test (GHT; SITA-Standard 30-2 program), the COV and ICC were examined in patients with (GHT+; 38 eyes, M:F = 20:18, average age 48.9 ± 12.8 years) and without (GHT-; 27 eyes, M:F = 13:14, average age 50.1 ± 8.7 years) abnormal glaucomatous visual fields.
Results: FOR ALL SUBJECTS, THE INTRASESSION REPRODUCIBILITY OF MBR IN THE OPTIC DISK (COV: 3.4 ± 2.0; ICC: 0.95) and choroid (COV: 4.7 ± 3.4; ICC: 0.98) was excellent. The reproducibility for the retinal vein (COV: 8.4 ± 5.6, ICC: 0.90) and retinal artery (COV: 10.9 ± 9.9, ICC: 0.9) was moderate. MBRs in the optic disk had good reproducibility in both the GHT+ group (COV: 3.8 ± 2.0; ICC: 0.97) and the GHT- group (COV: 2.9 ± 2.1; ICC: 0.95). Local assessment of the optic disk in normal or glaucoma patients showed that the COVs of the quadrant optic disk areas were best in the temporal area of MBR (3.4%, 4.2%, respectively).
Conclusion: LSFG-NAVI showed favorable reproducibility in evaluation of retinal circulation of glaucoma patients, particularly in the optic disk and choroid.
Keywords: ocular circulation; optic nerve; reproducibility; retina.
Figures
References
-
- Le A, Mukesh BN, McCarty CA, Taylor HR. Risk factors associated with the incidence of open-angle glaucoma: the visual impairment project. Invest Ophthalmol Vis Sci. 2003;44(9):3783–3789. - PubMed
-
- Suzuki Y, Iwase A, Araie M, et al. Risk factors for open-angle glaucoma in a Japanese population: the Tajimi Study. Ophthalmology. 2006;113(9):1613–1617. - PubMed
-
- Caprioli J, Coleman AL. Blood pressure, perfusion pressure, and glaucoma. Am J Ophthalmol. 2010;149(5):704–712. - PubMed
LinkOut - more resources
Full Text Sources
Research Materials