A mannequin study of intubation with the AP advance and GlideScope Ranger videolaryngoscopes and the Macintosh laryngoscope
- PMID: 21890882
- DOI: 10.1213/ANE.0b013e3182288bda
A mannequin study of intubation with the AP advance and GlideScope Ranger videolaryngoscopes and the Macintosh laryngoscope
Abstract
Background: The AP Advance (APA) is a videolaryngoscope with interchangeable blades: intubators can choose standard Macintosh blades or a difficult-airway blade with increased curvature and a channel to guide the tube to the larynx. The APA may therefore be comparably effective in both normal and difficult airways. We tested the hypotheses that intubation with the APA is no slower than Macintosh laryngoscopy for normal mannequin airways, and that it is no slower than videolaryngoscopy using a GlideScope Ranger in difficult mannequin airways.
Methods: Medical professionals whose roles potentially include tracheal intubation were trained with each device. Participants intubated simulated (Laerdal SimMan) normal and difficult airways with the APA, GlideScope, and a conventional Macintosh blade. Speed of intubation was compared using Cox proportional hazards regression, with a hazard ratio >0.8 considered noninferior. We also compared laryngeal visualization, failures, and participant preferences.
Results: Unadjusted intubation times in the normal airway with the APA and Macintosh were virtually identical (median, 22 vs 23 seconds); after adjustment for effects of experience, order, and period, the hazard ratio (95% confidence interval) comparing APA with Macintosh laryngoscopy was 0.87 (0.65, 1.17), which was not significantly more than our predefined noninferiority boundary of 0.8 (P = 0.26). Intubation with the APA was faster than with the GlideScope in difficult airways (hazard ratio = 7.6 [5.0, 11.3], P < 0.001; median, 20 vs 59 seconds). All participants intubated the difficult airway mannequin with the APA, whereas 33% and 37% failed with the GlideScope and Macintosh, respectively. In the difficult airway, 99% of participants achieved a Cormack and Lehane grade I to II view with the APA, versus 85% and 33% with the GlideScope and Macintosh, respectively. When asked to choose 1 device overall, 82% chose the APA.
Conclusions: Intubation times were similar with the APA and Macintosh laryngoscopes in mannequins with normal airways. However, intubation with the APA was significantly faster than with the GlideScope in the difficult mannequin simulation.
Similar articles
-
Paramedic laryngoscopy in the simulated difficult airway: comparison of the Venner A.P. Advance and GlideScope Ranger video laryngoscopes.Acad Emerg Med. 2011 Jul;18(7):692-8. doi: 10.1111/j.1553-2712.2011.01115.x. Acad Emerg Med. 2011. PMID: 21762232 Clinical Trial.
-
A Macintosh laryngoscope blade for videolaryngoscopy reduces stylet use in patients with normal airways.Anesth Analg. 2009 Sep;109(3):825-31. doi: 10.1213/ane.0b013e3181ae39db. Anesth Analg. 2009. PMID: 19690253 Clinical Trial.
-
Comparison of intubation success of video laryngoscopy versus direct laryngoscopy in the difficult airway using high-fidelity simulation.Simul Healthc. 2009 Fall;4(3):160-5. doi: 10.1097/SIH.0b013e318197d2e5. Simul Healthc. 2009. PMID: 19680083
-
Should the Glidescope video laryngoscope be used first line for all oral intubations or only in those with a difficult airway? A review of current literature.J Perioper Pract. 2018 Dec;28(12):322-333. doi: 10.1177/1750458918788985. Epub 2018 Jul 23. J Perioper Pract. 2018. PMID: 30035689
-
Videolaryngoscope designs for tracheal intubation in adults: a systematic review with network meta-analysis of randomised controlled trials.Anaesthesia. 2025 Jul;80(7):823-833. doi: 10.1111/anae.16597. Epub 2025 Mar 11. Anaesthesia. 2025. PMID: 40069118
Cited by
-
Medico-legal liability of injuries arising from laryngoscopy.J Laryngol Otol. 2024 May;138(5):554-558. doi: 10.1017/S0022215123001986. Epub 2023 Nov 20. J Laryngol Otol. 2024. PMID: 37982243 Free PMC article.
-
An Evaluation of the Intubrite Laryngoscope in Simulated In-Hospital and Out-of-Hospital Settings by Individuals with No Clinical Experience: A Randomized, Cross-Over, Manikin Study.Diagnostics (Basel). 2022 Jul 5;12(7):1633. doi: 10.3390/diagnostics12071633. Diagnostics (Basel). 2022. PMID: 35885537 Free PMC article.
-
Intubation performance using different laryngoscopes while wearing chemical protective equipment: a manikin study.BMJ Open. 2016 Mar 15;6(3):e010250. doi: 10.1136/bmjopen-2015-010250. BMJ Open. 2016. PMID: 27008688 Free PMC article.
-
Comparative evaluation of intubation performances using two different barrier devices used in the COVID-19 era: A manikin based pilot study.Saudi J Anaesth. 2021 Apr-Jun;15(2):86-92. doi: 10.4103/sja.sja_1062_20. Epub 2021 Apr 1. Saudi J Anaesth. 2021. PMID: 34188622 Free PMC article.
-
A review of the literature: direct and video laryngoscopy with simulation as educational intervention.Adv Med Educ Pract. 2014 Jan 28;5:15-23. doi: 10.2147/AMEP.S51963. eCollection 2014. Adv Med Educ Pract. 2014. PMID: 24501548 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources