Reference system for cholesterol measurements
- PMID: 2189207
Reference system for cholesterol measurements
Abstract
A reference system for cholesterol measurement is necessary to assure accuracy of cholesterol measurements by clinical, research, and manufacturers' laboratories. Such a reference system is based on the collaboration of laboratory and clinical professionals, research groups, professional societies, government groups, and manufacturers of diagnostic products. Essential components include a definitive method, a reference method, and commutable reference materials that are accurately labeled and have long-term stability. A mechanism by which clinical, research, and manufacturers' laboratories can establish traceability to the reference system is also needed. In the United States, the NRS/CHOL was organized as part of the National Reference System for the Clinical Laboratory. The major organizational components of the NRS/CHOL include the National Institute for Standards and Technology, the CDC, the CRMN, the CAP, the AAB, regional reference programs, and manufacturers of cholesterol diagnostic products. The NIST maintains an isotope dilution-mass spectrometer definitive method and distributes certified reference materials. The CDC maintains a modified Abell-Levy-Brodie-Kendall reference method and offers a CDC-NHLBI Lipid Standardization Program; the CRMN provides reference method analyses on specimens furnished by manufacturers and clinical or research laboratories; CAP, AAB, and regional reference programs provide either proficiency testing, quality assurance programs, or both; and manufacturers assure that results on diagnostic products are the same as those achieved when using fresh patient specimens and the NRS/CHOL reference method. The NRS/CHOL has contributed much to the success of clinical epidemiologic and research and development investigations in coronary heart disease.
Similar articles
-
The Centers for Disease Control-National Heart, Lung and Blood Institute Lipid Standardization Program. An approach to accurate and precise lipid measurements.Clin Lab Med. 1989 Mar;9(1):105-35. Clin Lab Med. 1989. PMID: 2538292 Review.
-
Matrix effects on proficiency testing materials. Impact on accuracy of cholesterol measurement in laboratories in the nation's largest hospital system.Arch Pathol Lab Med. 1993 Apr;117(4):345-51. Arch Pathol Lab Med. 1993. PMID: 8466396
-
A reference method laboratory network for cholesterol: a model for standardization and improvement of clinical laboratory measurements.Clin Chem. 2000 Nov;46(11):1762-72. Clin Chem. 2000. PMID: 11067811
-
The accuracy of laboratory measurements in clinical chemistry: a study of 11 routine chemistry analytes in the College of American Pathologists Chemistry Survey with fresh frozen serum, definitive methods, and reference methods.Arch Pathol Lab Med. 1998 Jul;122(7):587-608. Arch Pathol Lab Med. 1998. PMID: 9674541
-
The need for accurate total cholesterol measurement. Recommended analytical goals, current state of reliability, and guidelines for better determinations.Clin Lab Med. 1989 Mar;9(1):37-60. Clin Lab Med. 1989. PMID: 2647375 Review.
Cited by
-
Prevalence of coronary heart disease risk factors and screening for high cholesterol levels among young adults, United States, 1999-2006.Ann Fam Med. 2010 Jul-Aug;8(4):327-33. doi: 10.1370/afm.1137. Ann Fam Med. 2010. PMID: 20644187 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical
Miscellaneous