[Supraglottic airway devices]
- PMID: 21894593
- DOI: 10.1055/s-0031-1286612
[Supraglottic airway devices]
Abstract
Supraglottic airway devices are developed with increasing frequency following the overwhelming success of the laryngeal mask airway (LMA). In contrast to the first generation devices such as the 'classic' LMA and the laryngeal tube second generation devices usually offer an oesophageal drainage tube and/or an improved oropharyngeal leak pressure during positive pressure ventilation such as the laryngeal mask ProSeal and the laryngeal tube S. Recently the disposable versions of these supraglottic airway devices and the novel I-Gel mask have gained increasing interest. Both the LMA and the PLMA have been shown to be perfectly suitable for routine anaesthesia and emergency airway management. While the lacking protection against aspiration is still considered a major limitation of the LMA, the value of airway devices with an oesophageal drainage tube in this respect remains untermined at present.
© Georg Thieme Verlag Stuttgart · New York.
Similar articles
-
Supraglottic airway devices.Best Pract Res Clin Anaesthesiol. 2005 Dec;19(4):581-93. doi: 10.1016/j.bpa.2005.08.005. Best Pract Res Clin Anaesthesiol. 2005. PMID: 16408535 Review.
-
A comparison of various supraglottic airway devices for fiberoptical guided tracheal intubation.Braz J Anesthesiol. 2017 Mar-Apr;67(2):166-171. doi: 10.1016/j.bjane.2015.09.007. Epub 2016 May 26. Braz J Anesthesiol. 2017. PMID: 28236864 Clinical Trial.
-
In a difficult access scenario, supraglottic airway devices improve success and time to ventilation.Eur J Emerg Med. 2015 Oct;22(5):374-6. doi: 10.1097/MEJ.0000000000000230. Eur J Emerg Med. 2015. PMID: 25460811
-
The distance between the glottis and the cuff of a tracheal tube placed through three supraglottic airway devices in children: A randomised controlled trial.Eur J Anaesthesiol. 2019 Oct;36(10):721-727. doi: 10.1097/EJA.0000000000001070. Eur J Anaesthesiol. 2019. PMID: 31415305 Clinical Trial.
-
Laryngeal mask airway ProSeal provides higher oropharyngeal leak pressure than i-gel in adult patients under general anesthesia: a meta-analysis.J Clin Anesth. 2016 Sep;33:298-305. doi: 10.1016/j.jclinane.2016.04.020. Epub 2016 May 18. J Clin Anesth. 2016. PMID: 27555181 Review.
Cited by
-
Emergency medicine techniques and the forensic autopsy.Forensic Sci Med Pathol. 2013 Mar;9(1):48-67. doi: 10.1007/s12024-012-9366-6. Epub 2012 Aug 8. Forensic Sci Med Pathol. 2013. PMID: 22872361 Review.
-
A comparison of blind intubation with the intubating laryngeal mask FASTRACH™ and the intubating laryngeal mask Ambu Aura-i™ a prospective randomised clinical trial.BMC Anesthesiol. 2019 Mar 30;19(1):44. doi: 10.1186/s12871-019-0718-6. BMC Anesthesiol. 2019. PMID: 30927922 Free PMC article. Clinical Trial.
-
Supraglottic Airway Devices for Elective Pediatric Anesthesia: I-gel versus Air-Q, Which is the Best?Anesth Essays Res. 2020 Jul-Sep;14(3):461-466. doi: 10.4103/aer.AER_107_20. Epub 2021 Mar 22. Anesth Essays Res. 2020. PMID: 34092859 Free PMC article.
-
Comparison of endotracheal intubation, combitube, and laryngeal mask airway between inexperienced and experienced emergency medical staff: A manikin study.Int J Crit Illn Inj Sci. 2014 Oct-Dec;4(4):303-8. doi: 10.4103/2229-5151.147533. Int J Crit Illn Inj Sci. 2014. PMID: 25625062 Free PMC article.